Evidence map›Paper›PMID 39621182›Full record

ArticleJournal of ophthalmic inflammation and infection2024

Automatic measurement of choroidal thickness with swept-source optical coherence tomography in chronic Vogt-Koyanagi-Harada disease: 3 years' follow-up.

Liria Yamamoto-Rodríguez, Alexander Anduaga-Beramendi, Roger Mediavilla-Vallespín, Olaia Subirà, Pere Garcia-Bru, Xavier Solanich-Moreno, Luis Arias, Josep M Caminal, Olga García-García

Abstract read
In one paragraph

Article in Journal of ophthalmic inflammation and infection, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Liria Yamamoto-RodríguezOphthalmology Department, University Hospital of Bellvitge, Hospitalet de Llobregat, Carrer Feixa Llarga S/N, Barcelona, 08907, Spain. liriayamamoto@gmail.com.ORCID http://orcid.org/0000-0003-0102-7996
Alexander Anduaga-BeramendiOphthalmology Department, University Hospital of Bellvitge, Hospitalet de Llobregat, Carrer Feixa Llarga S/N, Barcelona, 08907, Spain.
Roger Mediavilla-VallespínOphthalmology Department, University Hospital of Bellvitge, Hospitalet de Llobregat, Carrer Feixa Llarga S/N, Barcelona, 08907, Spain.
Olaia SubiràOphthalmology Department, University Hospital of Bellvitge, Hospitalet de Llobregat, Carrer Feixa Llarga S/N, Barcelona, 08907, Spain.
Pere Garcia-BruOphthalmology Department, University Hospital of Bellvitge, Hospitalet de Llobregat, Carrer Feixa Llarga S/N, Barcelona, 08907, Spain.
Xavier Solanich-MorenoInternal Medicine Department, University Hospital of Bellvitge, Hospitalet de Llobregat, Barcelona, Spain.
Luis AriasOphthalmology Department, University Hospital of Bellvitge, Hospitalet de Llobregat, Carrer Feixa Llarga S/N, Barcelona, 08907, Spain.
Josep M CaminalOphthalmology Department, University Hospital of Bellvitge, Hospitalet de Llobregat, Carrer Feixa Llarga S/N, Barcelona, 08907, Spain.
Olga García-GarcíaOphthalmology Department, University Hospital of Bellvitge, Hospitalet de Llobregat, Carrer Feixa Llarga S/N, Barcelona, 08907, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe course of Vogt-Koyanagi-Harada (VKH) disease is typically assessed qualitatively using indocyanine green angiography (ICGA) and enhanced-depth imaging optical coherence tomography (EDI-OCT). However, a quantitative approach could improve accuracy and objectivity. The aim of this study was to assess the clinical value of the automated measurement capabilities of swept-source optical coherence tomography (SS-OCT) to measure choroidal thickness (quantitative approach) in chronic VKH.

methodsProspective, longitudinal case-control study at a tertiary university hospital involving 23 chronic VKH patients (9 convalescent and 14 quiescent) and 17 age-matched controls. Choroidal thickness was automatically measured with SS-OCT.

resultsChoroidal thinning and improved vision were associated with treatment while increasing thickness and worsening vision were associated with posterior relapse. Overall, 41.6% of asymptomatic (no change in visual acuity) recurrences in the convalescent group and 25% of recurrences in the quiescent group were detected by SS-OCT. All recurrences diagnosed by SS-OCT showed signs of inflammation on ICGA.

conclusionsAutomatic measurement of choroidal thickness with SS-OCT is a rapid, non-invasive method of detecting posterior segment recurrences and treatment response in VKH patients, and could reduce the need for angiography to monitor this disease.

Indexed as

ChoroidChronicIndocyanine green angiographyRelapsesSwept-source-OCTThicknessVogt-Koyanagi-Harada

Identifiers

PMID39621182
PMCPMC11612052

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.