Evidence map›Paper›PMID 39620912›Full record

ArticleJournal of applied clinical medical physics2025

Five-year evaluation of linear accelerator-based SRS platform isocentricity.

Yohan A Walter, Anne N Hubbard, Phillip F Durham, Hsinshun T Wu

Abstract readEvaluation Study
In one paragraph

Article in Journal of applied clinical medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Five-year evaluation of linear accelerator-based SRS platform isocentricity.Journal of applied clinical medical physics · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Yohan A WalterDepartment of Radiation Oncology, Willis Knighton Cancer Center, Shreveport, Louisiana, USA.ORCID https://orcid.org/0000-0003-3758-9093
Anne N HubbardDepartment of Radiation Oncology, Willis Knighton Cancer Center, Shreveport, Louisiana, USA.
Phillip F DurhamDepartment of Radiation Oncology, Willis Knighton Cancer Center, Shreveport, Louisiana, USA.
Hsinshun T WuDepartment of Radiation Oncology, Willis Knighton Cancer Center, Shreveport, Louisiana, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Linear accelerator (LINAC)-based stereotactic radiosurgery (SRS) has become a mainstay in the management of intracranial tumors. However, the high fractional doses and sharp gradients used in SRS place heavy demands on geometric accuracy. Image guidance systems such as ExacTrac (ETX, Brainlab AG, Munich, Germany) have been developed to facilitate position verification at nonzero table angles. Though convenient, potential loss of mechanical rigidity between the imaging and treatment systems can be cause for concern, as the ETX system is not mounted to the rotating gantry. In this retrospective study, we analyzed 518 Winston-Lutz (WL) tests performed in the last 5 years with ETX alignment on our Elekta Versa HD (Elekta AB, Stockholm, Sweden) linear accelerator to determine the achievable limits of precision and stability over time for our LINAC-based SRS platform. Results demonstrated remarkable stability over time. 3D and directional misalignments never exceeded 1.0 mm over the study period; however, table rotation was shown to be the most significant source of positional uncertainty. Gantry sag, as measured by gun-to-target misalignments at the gantry-0 and gantry-180-degree positions, was consistent, measuring 1.23 ± 0.18 mm over the study period. Measured accuracy was well within acceptable tolerances for cranial SRS treatment delivery. Notably, the use of the ETX system for intrafraction repositioning effectively eliminates couch walkout, the most significant source of uncertainty identified in this study. Our results thus corroborate safe SRS treatment delivery on our Versa HD with ExacTrac image guidance.

Indexed as

Brain NeoplasmsParticle AcceleratorsPhantoms, ImagingRadiosurgeryRadiotherapy Planning, Computer-AssistedHumansRadiotherapy DosageRadiotherapy, Intensity-ModulatedRetrospective Studieslinear acceleratorQAquality assuranceSRSSRTstereotactic radiosurgery

Identifiers

PMID39620912
PMCPMC11969110

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.