Evidence map›Paper›PMID 39619583›Full record

ArticleHeliyon2024

A newly custom coordinate system used for preoperative planning of robotic-assisted total knee arthroplasty.

Hua Qiao, Runzhi Xia, Yongyun Chang, Keyu Kong, Minghao Jin, Zanjing Zhai, Jingwei Zhang, Huiwu Li

Abstract read
In one paragraph

Article in Heliyon, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Hua QiaoShanghai Key Laboratory of Orthopedics Implants, Shanghai Ninth People's Hospital, Department of Orthopedics Surgery, Shanghai Jiaotong University School of Medicine, Shanghai, 200011, PR China.
Runzhi XiaShanghai Key Laboratory of Orthopedics Implants, Shanghai Ninth People's Hospital, Department of Orthopedics Surgery, Shanghai Jiaotong University School of Medicine, Shanghai, 200011, PR China.
Yongyun ChangShanghai Key Laboratory of Orthopedics Implants, Shanghai Ninth People's Hospital, Department of Orthopedics Surgery, Shanghai Jiaotong University School of Medicine, Shanghai, 200011, PR China.
Keyu KongShanghai Key Laboratory of Orthopedics Implants, Shanghai Ninth People's Hospital, Department of Orthopedics Surgery, Shanghai Jiaotong University School of Medicine, Shanghai, 200011, PR China.
Minghao JinShanghai Key Laboratory of Orthopedics Implants, Shanghai Ninth People's Hospital, Department of Orthopedics Surgery, Shanghai Jiaotong University School of Medicine, Shanghai, 200011, PR China.
Zanjing ZhaiShanghai Key Laboratory of Orthopedics Implants, Shanghai Ninth People's Hospital, Department of Orthopedics Surgery, Shanghai Jiaotong University School of Medicine, Shanghai, 200011, PR China.
Jingwei ZhangShanghai Key Laboratory of Orthopedics Implants, Shanghai Ninth People's Hospital, Department of Orthopedics Surgery, Shanghai Jiaotong University School of Medicine, Shanghai, 200011, PR China.
Huiwu LiShanghai Key Laboratory of Orthopedics Implants, Shanghai Ninth People's Hospital, Department of Orthopedics Surgery, Shanghai Jiaotong University School of Medicine, Shanghai, 200011, PR China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Preoperative planning is critical for total knee arthroplasty (TKA) performed with surgical robots, as it involves establishing a coordinate system to calculate the angle values of the components. This coordinate system serves as a reference during the surgical planning stage. This study aimed to develop a newly custom coordinate system suitable for integration with a surgical robot system. Methods: The "Skywalker" surgical robot system was used to import computed tomography (CT) images of the entire lower extremities from 50 patients diagnosed with osteoarthritis. Three-dimensional reconstruction was subsequently performed. The TKA component was positioned at a fixed angle using the newly developed custom coordinate system. The angle values of the components, based on the standard CT coordinate system, were then recorded without altering their positioning. These values were analyzed to assess the differences between the two coordinate systems. Results: The mean and standard deviation values for the coronal, sagittal, and transverse plane positioning of the femoral component (absolute value of error) were 0.004° ± 0.020°, 0.006° ± 0.024°, and 0.158° ± 0.186°, respectively. Similarly, the mean and standard deviation values for the coronal, sagittal, and transverse plane positioning of the tibial component (absolute value of error) were 0.544° ± 0.452°, 0.042° ± 0.076°, and 0.348° ± 0.445°, respectively. Conclusion: This newly developed custom coordinate system can be employed for preoperative planning in

Indexed as

Coordinate systemKnee osteoarthritisSurgical robotTotal knee arthroplasty

Identifiers

PMID39619583
PMCPMC11605408

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.