Evidence map›Paper›PMID 39618960›Full record

ArticleJGH open : an open access journal of gastroenterology and hepatology2024

Safety and performance of the HYBRIDknife flex in a porcine model of esophageal endoscopic submucosal dissection: A pilot study.

Christopher J L Khor, Katsuro Ichimasa, Stephen K K Tsao, Ulrich Biber, Yutaka Saito

Abstract read
In one paragraph

Article in JGH open : an open access journal of gastroenterology and hepatology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Colorectal Endoscopic Submucosal Dissection Using a Single Multifunctional Knife With a High-Pressure Waterjet System.Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Christopher J L KhorSingapore General Hospital Singapore and Duke-NUS Medical School Singapore Singapore.ORCID https://orcid.org/0000-0002-1409-5691
Katsuro IchimasaShowa University Northern Yokohama Hospital Yokohama Japan.
Stephen K K TsaoAliveo Medical Singapore Singapore.
Ulrich BiberErbe Elektromedizin GmbH Tuebingen Germany.ORCID https://orcid.org/0000-0001-9788-1761
Yutaka SaitoEndoscopy Division National Cancer Center Hospital Tokyo Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and Aim: Endoscopic submucosal dissection (ESD) is considered the best modality for achieving en bloc resection of larger neoplastic mucosal lesions in the upper and lower gastrointestinal (GI) tract. Multiple devices are available for ESD, and refinements continue to be made to develop devices that improve the safety and efficiency of performing ESD. Submucosal injection with viscous fluids like glycerol, which prolong submucosal expansion, could facilitate the procedure. We aimed to evaluate the safety and performance of the new Erbe HYBRIDknife® flex, which combines electrosurgical dissection with waterjet-assisted injection in a slim and flexible form factor. Methods: In a prospective animal study with six pigs, four endoscopists, each with 10-20 years of experience in ESD, performed 28 esophageal ESDs. One half was performed with physiological saline injectate, the other half with fructose-added glycerol. Various performance aspects were evaluated on a five-point scale [5 = best], including dissection properties, handling, and usability. Results: No perforations or major bleeding occurred. All resections were performed en bloc, with one technical failure (3.6%, 1 of 28). Performance scores were similar for saline and glycerol (4.5 ± 0.31 vs. 4.5 ± 0.32, Conclusions: We demonstrated that esophageal ESD can be performed safely and rapidly using HYBRIDknife flex, with excellent performance evaluation by the endoscopists. Combining this device with glycerol or saline is precise and effective for ESD, although experience could compensate for the theoretical disadvantage of using normal saline.

Indexed as

electrosurgeryendoscopic resectionendoscopic submucosal dissectiongastrointestinal endoscopyglycerol

Identifiers

PMID39618960
PMCPMC11606903

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked