Microbiological indoor air quality and associated factors in private clinics of Harar Town, Eastern Ethiopia.

Liku Muche Temesgen, Tamagnu Sintie Alamirew, Salie Mulat Endalew, Bealemlay Abebe Melake, Wegene Deriba Regassa, Sina Temesgen Tolera, Molla Getie Mehari

Abstract read
In one paragraph

Article in Multidisciplinary respiratory medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Liku Muche TemesgenSchool of Environmental Health, College of Health and Medical Sciences, Haramaya University, Harar, Ethiopia.ORCID 0000-0002-1292-0125
Tamagnu Sintie AlamirewSchool of Environmental Health, College of Health and Medical Sciences, Haramaya University, Harar, Ethiopia.ORCID 0009-0007-9006-4778
Salie Mulat EndalewSchool of Environmental Health, College of Health and Medical Sciences, Haramaya University, Harar, Ethiopia.ORCID 0000-0003-3964-1449
Bealemlay Abebe MelakeSchool of Environmental Health, College of Health and Medical Sciences, Haramaya University, Harar, Ethiopia.ORCID 0000-0003-1661-6961
Wegene Deriba RegassaSchool of Environmental Health, College of Health and Medical Sciences, Haramaya University, Harar, Ethiopia.
Sina Temesgen ToleraSchool of Environmental Health, College of Health and Medical Sciences, Haramaya University, Harar, Ethiopia.ORCID 0000-0002-6489-3923
Molla Getie MehariDepartment of Medical Laboratory Science.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIndoor air pollution, including airborne microorganisms, can cause allergies, respiratory diseases, and immune-toxic diseases. Sneezing generates millions of airborne microbial infections, and ventilation sources alter microbial communities. Few studies exist in developing countries, including Ethiopia, and Harar Town. The aim is to assess microbial indoor air quality and associated factors among private clinics, Harar town, Eastern Ethiopia. METHODOLOGY: A cross-sectional study was conducted on 260 private clinic rooms in Harar town, using a systematic random sampling method and passive air sampling. Data was collected using the settle plate method and an observation checklist. Bivariate and multivariate analysis was performed using binary logistic regression, with a P-value of <0.05 considered statistically significant.

resultThe minimum and maximum bacterial loads were 3933 CFU/m3 and 92 CFU/m3 respectively. Based on the pollution degree of the European Commission, the Mean bacterial load (904 CFU/m3) was at higher bacterial load. The highest, lowest, and mean fungal loads were 1967 CFU/m3, 9 CFU/m3 and 401 CFU/m3 respectively. Temperature of <25 °C (AOR = 1.58, p = 0.04, and 95% CI = 1.05, 1.91), >28 °C (AOR = 1.23, P = 0.03, and 95% CI = 1.51, 2.02) were significantly associated with bacterial indoor air quality. Relative humidity of treatment rooms (AOR = 1.87, p = 0.02, and 95% CI = 1.21, 3.09) had an association with bacterial loads. The clinic treatment rooms with a recorded temperature <25 °C (AOR = 6.32, p = 0.01, and 95% CI = 6.10, 8.25) had associated with fungal loads. But the rooms having a temperature of >28 °C (AOR = 0.41, p = 0.04, and 95% CI = 0.31, 0.78) were 59% less likely to comply with the fungal standards compared to rooms having a temperature of 25-28 °C. The clinic rooms with a relative humidity of <30% (AOR = 7.75, p = 0.02, 95% CI = 7.21, 8.39) were 7.75 times more likely to comply with those with a relative humidity of > 60% in the treatment rooms.

conclusionPrivate clinics in Harar had a moderate fungal load and a higher indoor air bacterial concentration when compared to different indoor air standards. Temperature, humidity, inadequate ventilation and the presence of unsanitary attached toilets are some variables associated with microbial loads.