ArticleJournal of applied clinical medical physics2025

Evaluating the dosimetric impact of deep-learning-based auto-segmentation in prostate cancer radiotherapy: Insights into real-world clinical implementation and inter-observer variability.

Najmeh Arjmandi, Mohammad Amin Mosleh-Shirazi, Shokoufeh Mohebbi, Shahrokh Nasseri, Alireza Mehdizadeh, Zohreh Pishevar, Sare Hosseini, Amin Amiri Tehranizadeh, Mehdi Momennezhad

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Review
  9. Review
  10. Article
  11. Review
  12. Article
  13. Article
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Najmeh ArjmandiDepartment of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.
Mohammad Amin Mosleh-ShiraziPhysics Unit, Department of Radio-Oncology, Shiraz University of Medical Sciences, Shiraz, Iran.
Shokoufeh MohebbiMedical Physics Department, Reza Radiation Oncology Center, Mashhad, Iran.
Shahrokh NasseriDepartment of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.
Alireza MehdizadehIonizing and Non-Ionizing Radiation Protection Research Center, School of Paramedical Sciences, Shiraz University of Medical Sciences, Shiraz, Iran.
Zohreh PishevarDepartment of Radiation Oncology, Mashhad University of Medical Sciences, Mashhad, Iran.
Sare HosseiniDepartment of Radiation Oncology, Mashhad University of Medical Sciences, Mashhad, Iran.
Amin Amiri TehranizadehDepartment of Medical Informatics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.
Mehdi MomennezhadDepartment of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.ORCID https://orcid.org/0000-0002-1509-0446

Funding

Mashhad University of Medical Sciences
6 · The paper itself

Abstract

purposeThis study aimed to investigate the dosimetric impact of deep-learning-based auto-contouring for clinical target volume (CTV) and organs at risk (OARs) delineation in prostate cancer radiotherapy planning. Additionally, we compared the geometric accuracy of auto-contouring system to the variability observed between human experts.

methodsWe evaluated 28 planning CT volumes, each with three contour sets: reference original contours (OC), auto-segmented contours (AC), and expert-defined manual contours (EC). We generated 3D-CRT and intensity-modulated radiation therapy (IMRT) plans for each contour set and compared their dosimetric characteristics using dose-volume histograms (DVHs), homogeneity index (HI), conformity index (CI), and gamma pass rate (3%/3 mm).

resultsThe geometric differences between automated contours and both their original manual reference contours and a second set of manually generated contours are smaller than the differences between two manually contoured sets for bladder, right femoral head (RFH), and left femoral head (LFH) structures. Furthermore, dose distribution accuracy using planning target volumes (PTVs) derived from automatically contoured CTVs and auto-contoured OARs demonstrated consistency with plans based on reference contours across all evaluated cases for both 3D-CRT and IMRT plans. For example, in IMRT plans, the average D

conclusionOur automated contouring system can reduce inter-expert variability and achieve dosimetric accuracy comparable to gold standard reference contours, highlighting its potential for streamlining clinical workflows. The quantitative analysis revealed no consistent trend of increasing or decreasing PTVs derived from automatically contoured CTVs and OAR doses due to automated contours, indicating minimal impact on treatment outcomes. These findings support the clinical feasibility of utilizing our deep-learning-based auto-contouring model for prostate cancer radiotherapy planning.

Indexed as

Deep LearningOrgans at RiskProstatic NeoplasmsRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedFeasibility StudiesHumansImaging, Three-DimensionalMaleObserver VariationProstateRadiometryRadiotherapy DosageRetrospective StudiesTomography, X-Ray Computedauto‐contouringdeep learninginter‐observer variabilityprostate segmentationradiotherapy treatment planning

Identifiers

PMID39616629
PMCPMC11905246

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.