ArticleBiological trace element research2025
Establishment and Validation of Sandell-Kolthoff Method for Saliva Iodine Determination.
Article in Biological trace element research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors.
Funding
Abstract
Saliva iodine is a useful biochemical marker for evaluating iodine status and controlling iodine-related diseases. This study aims to establish and validate a simple, reliable, and low-cost Sandell-Kolthoff (S-K) method for the determination of iodine in saliva. The method was established by considering the digestion solution type, concentration, dosage, digestion time and temperature, the volume of saliva samples, glass tube size, dosage of arsenious acid solution and ammonium ceric sulfate solution, and warm bath time. Then, the effectiveness of the method was examined by the linearity of the standard curve, detection limit, precision, and accuracy. The 1.5 mL 1 Mol/L ammonium persulfate solution at 100 °C for 90 min, the 200 μL saliva sample, glass tubes of 15 mm × 120 mm, 2.5 mL arsenious acid solution, 0.3 mL ammonium ceric sulfate solution, and 15 min for warm bath was selected to determine saliva iodine. In terms of validation of the S-K method, the linearity method has the linear range of the standard curve from 0 to 300 μg/L and the coefficient of determination ≥ 0.999; the detection limit, when the volume of saliva samples was 0.2 mL, was 4.6 μg/L; for precision, the relative standard deviation was from 0.3 to 2.8%; and for accuracy, the total recovery rate ranged from 92.8 to 107.0%. This S-K method is easy to operate, has good precision and accuracy, and can be used as a method to determine saliva iodine. It has great potential practical value in disease prevention, clinical auxiliary diagnosis, and experimental research.
Indexed as
Identifiers
39614941What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.