ArticleJournal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology2024
Biomechanical evaluation of percutaneous compression plate and femoral neck system in Pauwels type III femoral neck fractures.
Article in Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- An Adams' Arch -based anatomical classification system guiding internal fixation strategies for non-displaced femoral neck fractures in elderly patients: a finite element analysis.BMC musculoskeletal disorders · 2026Article
- Does FNS outperform CCS in Pauwel's type III fracture fixation: a combined experimental and numerical study.Medical & biological engineering & computing · 2026Article
- Torsional Stability of the Femoral Neck System for Pauwels Type III Femoral Neck Fracture Fixation: A Finite-element Analysis.Journal of the American Academy of Orthopaedic Surgeons. Global research & reviews · 2026Article
- Femoral Neck System in Pauwell III Femoral Neck Fractures: A Bibliometric Analysis and Review.Cureus · 2026Review
- Early Outcome of Intracapsular Fracture Neck of Femur Managed with Femoral Neck System Versus Cannulated Cancellous Screws: A Prospective Comparative Study.Indian journal of orthopaedics · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
backgroundThe optimal treatment for Pauwels type III femoral neck fractures remains contentious. We aim to compare the biomechanical properties of three inverted cannulated compression screw (ICCS), femoral neck system (FNS), and percutaneous compression plate (PCCP) to determine which offers superior stability for unstable femoral neck fractures. MATERIALS AND
methodsFinite element analysis and artificial bone models were used to establish Pauwels III femoral neck fracture models. They were divided into ICCS, FNS, and PCCP groups based on respective internal fixation assemblies. The models were subjected to vertical axial loads (2100 N) and torsional forces (10 N × mm) along the femoral neck axis in the finite element analysis. The primary outcomes such as the Z axis fragmentary displacements, as well as displacements and the von Mises stress (VMS) distributions of internal fixations, were analyzed. Additionally, the artificial bones were subjected to progressively increasing vertical axial pressures and torsional moments at angles of 2°, 4°, and 6°, respectively. The vertical displacements of femoral heads and the required torque values were recorded.
resultsFinite element analysis revealed that under single-leg stance loading, the maximum Z-axis fragmentary displacements were 5.060 mm for ICCS, 4.028 mm for FNS, and 2.796 mm for PCCP. The maximum displacements of internal fixations were 4.545 mm for ICCS, 3.047 mm for FNS, and 2.559 mm for PCCP. Peak VMS values were 512.21 MPa for ICCS, 242.86 MPa for FNS, and 413.85 MPa for PCCP. Under increasing vertical loads applied to the artificial bones, the average vertical axial stiffness for the ICCS, FNS, and PCCP groups were 244.86 ± 2.84 N/mm, 415.03 ± 27.10 N/mm, and 529.98 ± 23.08 N/mm. For the torsional moment tests, the PCCP group demonstrated significantly higher torque values at 2°, 4°, and 6° compared with FNS and ICCS, with no significant difference between FNS and ICCS (P > 0.05).
conclusionsFinite element analysis and artificial bone models indicated that PCCP offers the best compressive and rotational stability for fixing Pauwels type III femoral neck fractures, followed by FNS and then ICCS. No significant difference in rotational resistance was observed between FNS and ICCS in synthetic bones. Level of Evidence Level 5.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.