ArticleAnalytical and bioanalytical chemistry2025
Improving signal-to-noise ratio of Raman measurements based on ensemble learning approach.
Article in Analytical and bioanalytical chemistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
Raman spectroscopy is an extensively explored vibrational spectroscopic technique to analyze the biochemical composition and molecular structure of samples, which is often assumed to be non-destructive when carefully using proper laser power and exposure time. However, the inherently weak Raman signal and concurrent fluorescence interference often lead to Raman measurements with a low signal-to-noise ratio (SNR), especially for biological samples. Great efforts have been made to develop experimental approaches and/or numerical algorithms to improve the SNR. In this study, we proposed an ensemble learning approach to recover and denoise Raman measurements with a low SNR. The proposed ensemble learning approach was evaluated on 986 pairs of Raman measurements, each pair of which consists of a low SNR Raman spectrum and a high SNR reference Raman spectrum from the exact same fungal sample but uses 200 times the integration time. Compared with conventional methods, the Raman measurements recovered by the proposed ensemble learning approach are more identical to high SNR reference Raman measurements, with an average RMSE and MAE of only 1.337 × 10
Indexed as
Identifiers
39613989What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.