Evidence map›Paper›PMID 39613854›Full record

ArticleEuropean archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery2025

Investigation of the coupling quality of partial prostheses at the stapes head.

Sijia Zhai, Till Moritz Eßinger, Martin Koch, Jianhang Deng, Thomas Zahnert, Marcus Neudert, Matthias Bornitz

Abstract read
In one paragraph

Article in European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Sijia ZhaiCarl Gustav Carus Faculty of Medicine, Department of Otorhinolaryngology, Head and Neck Surgery, Ear Research Center Dresden, Technische Universität Dresden, Fetscherstraße 74, 01307, Dresden, Germany. Sijia.Zhai@ukdd.de.ORCID http://orcid.org/0000-0003-2958-4145
Till Moritz EßingerCarl Gustav Carus Faculty of Medicine, Department of Otorhinolaryngology, Head and Neck Surgery, Ear Research Center Dresden, Technische Universität Dresden, Fetscherstraße 74, 01307, Dresden, Germany.
Martin KochCarl Gustav Carus Faculty of Medicine, Department of Otorhinolaryngology, Head and Neck Surgery, Ear Research Center Dresden, Technische Universität Dresden, Fetscherstraße 74, 01307, Dresden, Germany.
Jianhang DengCarl Gustav Carus Faculty of Medicine, Department of Otorhinolaryngology, Head and Neck Surgery, Ear Research Center Dresden, Technische Universität Dresden, Fetscherstraße 74, 01307, Dresden, Germany.
Thomas ZahnertCarl Gustav Carus Faculty of Medicine, Department of Otorhinolaryngology, Head and Neck Surgery, Ear Research Center Dresden, Technische Universität Dresden, Fetscherstraße 74, 01307, Dresden, Germany.
Marcus NeudertCarl Gustav Carus Faculty of Medicine, Department of Otorhinolaryngology, Head and Neck Surgery, Ear Research Center Dresden, Technische Universität Dresden, Fetscherstraße 74, 01307, Dresden, Germany.
Matthias BornitzCarl Gustav Carus Faculty of Medicine, Department of Otorhinolaryngology, Head and Neck Surgery, Ear Research Center Dresden, Technische Universität Dresden, Fetscherstraße 74, 01307, Dresden, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe success of partial ossicular chain reconstructions in cases of conductive hearing loss depends on many factors. One important factor is the coupling between the prosthesis and the stapes head, which has not been explicitly investigated previously. Prostheses with different forms of attachment to the stapes are available, namely clip and bell type PORP. We present a standardized method to assess the quality of the prosthesis-stapes connection. The coupling quality of different prostheses is compared using measurements on a specimen model.

methodsThis study delineated six groups categorized by prosthesis types, employing 12 temporal bones to create a reconstructed ossicular chain model. The model comprised stapes and inner ear of the specimen, various prostheses and a standardized mechanical excitation at the prosthesis head. Multiple-points measurements were conducted using laser Doppler vibrometry along the sound transfer direction. This methodology enabled the assessment of vibrational magnitude loss and sound distortion from the prosthesis to the stapes.

resultsAll six groups showed uniformly good sound transmission, with low magnitude loss of < 10 dB and very low total harmonic distortion of < 1%.

conclusionThe proposed measurement method enables an explicit and comparable examination of the prosthesis coupling to the stapes head. While the coupling mechanism may be important in terms of handling, stability or long-term robustness of the reconstruction, our results show no relevant differences between types in terms of sound transmission.

Indexed as

Hearing Loss, ConductiveOssicular ProsthesisOssicular ReplacementStapesHumansProsthesis DesignStapes SurgeryVibrationCouplingLaser doppler vibrometer (LDV)Middle ear reconstructionPartial ossicular replacement prosthesis (PORP)Total harmony distortion (THD)

Identifiers

PMID39613854
PMCPMC12055659

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.