Evidence map›Paper›PMID 39613452›Full record

Observational studyBMJ quality & safety2025

Large-scale observational study of AI-based patient and surgical material verification system in ophthalmology: real-world evaluation in 37 529 cases.

Hitoshi Tabuchi, Naofumi Ishitobi, Hodaka Deguchi, Yuta Nakaniida, Hayato Tanaka, Masahiro Akada, Mao Tanabe

Abstract readObservational Study
In one paragraph

Observational study in BMJ quality & safety, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Artificial intelligence in ophthalmology: opportunities, challenges, and ethical considerations.Medical hypothesis, discovery & innovation ophthalmology journal · 2025
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Hitoshi TabuchiDepartment of Technology and Design Thinking for Medicine, Hiroshima University, Hiroshima, Japan h.tabuchi@tsukazaki-eye.net.ORCID http://orcid.org/0000-0002-9098-0430
Naofumi IshitobiDepartment of Ophthalmology, Tsukazaki Hospital, Himeji, Japan.
Hodaka DeguchiDepartment of Ophthalmology, Tsukazaki Hospital, Himeji, Japan.
Yuta NakaniidaDepartment of Ophthalmology, Tsukazaki Hospital, Himeji, Japan.
Hayato TanakaDepartment of Ophthalmology, Tsukazaki Hospital, Himeji, Japan.
Masahiro AkadaDepartment of Ophthalmology, Tsukazaki Hospital, Himeji, Japan.
Mao TanabeDepartment of Ophthalmology, Tsukazaki Hospital, Himeji, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSurgical errors in ophthalmology can have devastating consequences. We developed an artificial intelligence (AI)-based surgical safety system to prevent errors in patient identification, surgical laterality and intraocular lens (IOL) selection. This study aimed to evaluate its effectiveness in real-world ophthalmic surgical settings.

methodsIn this retrospective observational before-and-after implementation study, we analysed 37 529 ophthalmic surgeries (18 767 pre-implementation, 18 762 post implementation) performed at Tsukazaki Hospital, Japan, between 1 March 2019 and 31 March 2024. The AI system, integrated with the WHO surgical safety checklist, was implemented for patient identification, surgical laterality verification and IOL authentication.

resultsPost implementation, five medical errors (0.027%) occurred, with four in non-authenticated cases (where the AI system was not fully implemented or properly used), compared with one (0.0053%) pre-implementation (p=0.125). Of the four non-authenticated errors, two were laterality errors during the initial implementation period and two were IOL implantation errors involving unlearned IOLs (7.3% of cases) due to delayed AI updates. The AI system identified 30 near misses (0.16%) post implementation, vs 9 (0.048%) pre-implementation (p=0.00067), surgical laterality errors/near misses occurred at 0.039% (7/18 762) and IOL recognition at 0.29% (28/9713). The system achieved>99% implementation after 3 months. Authentication performance metrics showed high efficiency: facial recognition (1.13 attempts, 11.8 s), surgical laterality (1.05 attempts, 3.10 s) and IOL recognition (1.15 attempts, 8.57 s). Cost-benefit analysis revealed potential benefits ranging from US$181 946.94 to US$2 769 129.12 in conservative and intermediate scenarios, respectively.

conclusionsThe AI-based surgical safety system significantly increased near miss detection and showed potential economic benefits. However, errors in non-authenticated cases underscore the importance of consistent system use and integration with existing safety protocols. These findings emphasise that while AI can enhance surgical safety, its effectiveness depends on proper implementation and continuous refinement.

Indexed as

Artificial IntelligenceMedical ErrorsOphthalmologic Surgical ProceduresOphthalmologyPatient Identification SystemsPatient SafetyAgedFemaleHumansJapanMaleMiddle AgedRetrospective StudiesIncident reportingMedical error, measurement/epidemiologyNear missPatient safetySurgery

Identifiers

PMID39613452
PMCPMC12229072

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.