Evidence map›Paper›PMID 39611809›Full record

ArticlemSystems2025

Quantifying synthetic bacterial community composition with flow cytometry: efficacy in mock communities and challenges in co-cultures.

Fabian Mermans, Ioanna Chatzigiannidou, Wim Teughels, Nico Boon

Abstract read
In one paragraph

Article in mSystems, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Fabian MermansGhent University, Center for Microbial Ecology and Technology (CMET), Faculty of Bioscience Engineering, Gent, Belgium.ORCID 0000-0003-2997-2885
Ioanna ChatzigiannidouGhent University, Center for Microbial Ecology and Technology (CMET), Faculty of Bioscience Engineering, Gent, Belgium.ORCID 0000-0002-1860-4967
Wim TeughelsDepartment of Oral Health Sciences, KU Leuven & Dentistry (Periodontology), University Hospitals Leuven, Leuven, Belgium.ORCID 0000-0001-7675-5643
Nico BoonGhent University, Center for Microbial Ecology and Technology (CMET), Faculty of Bioscience Engineering, Gent, Belgium.ORCID 0000-0002-7734-3103

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Determination of bacterial community composition in synthetic communities is critical for understanding microbial systems. The community composition is typically determined through bacterial plating or through PCR-based methods, which can be labor-intensive, expensive, or prone to bias. Simultaneously, flow cytometry has been suggested as a cheap and fast alternative. However, since the technique captures the phenotypic state of bacterial cells, accurate determination of community composition could be affected when bacteria are co-cultured. We investigated the performance of flow cytometry for quantifying oral synthetic communities and compared it to the performance of strain specific qPCR and 16S rRNA gene amplicon sequencing. Therefore, axenic cultures, mock communities and co-cultures of oral bacteria were prepared. Random forest classifiers trained on flow cytometry data of axenic cultures were used to determine the composition of the synthetic communities, as well as strain specific qPCR and 16S rRNA gene amplicon sequencing. Flow cytometry was shown to have a lower average root mean squared error and outperformed the PCR-based methods in even mock communities (flow cytometry: 0.11 ± 0.04; qPCR: 0.26 ± 0.09; amplicon sequencing: 0.15 ± 0.01). When bacteria were co-cultured, neither flow cytometry, strain-specific qPCR, nor 16S rRNA gene amplicon sequencing resulted in similar community composition. Performance of flow cytometry was decreased compared with mock communities due to changing phenotypes. Finally, discrepancies between flow cytometry and strain-specific qPCR were found. These findings highlight the challenges ahead for quantifying community composition in co-cultures by flow cytometry.IMPORTANCEQuantification of bacterial composition in synthetic communities is crucial for understanding and steering microbial interactions. Traditional approaches like plating, strain-specific qPCR, and amplicon sequencing are often labor-intensive and expensive and limit high-throughput experiments. Recently, flow cytometry has been suggested as a swift and cheap alternative for quantifying communities and has been successfully demonstrated on simple bacterial mock communities. However, since flow cytometry measures the phenotypic state of cells, measurements can be affected by differing phenotypes. Especially, changing phenotypes resulting from co-culturing bacteria can have a profound effect on the applicability of the technique in this context. This research illustrates the feasibility and challenges of flow cytometry for the determination of community structure in synthetic mock communities and co-cultures.

Indexed as

BacteriaFlow CytometryMicrobiotaCoculture TechniquesDNA, BacterialHumansRNA, Ribosomal, 16SDNA, BacterialRNA, Ribosomal, 16S16S rRNA gene amplicon sequencingflow cytometrymachine learningoral microbiologyrandom foreststrain specific qPCR

Identifiers

PMID39611809
PMCPMC11748490

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.