ArticleJournal of applied clinical medical physics2025

Evaluation of an improved picket fence style test for routine MLC positional QA.

Michael Barnes, Therese Standen, Renee Blackmore, Peter Greer

Abstract readEvaluation Study
In one paragraph

Article in Journal of applied clinical medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Review
  3. A multi-institution performance assessment of a double-layer MLC.Journal of applied clinical medical physics · 2025
    Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Michael BarnesDepartment of Radiation Oncology, Calvary Mater Hospital Newcastle, Newcastle, New South Wales, Australia.
Therese StandenDepartment of Radiation Oncology, Calvary Mater Hospital Newcastle, Newcastle, New South Wales, Australia.
Renee BlackmoreDepartment of Radiation Oncology, Calvary Mater Hospital Newcastle, Newcastle, New South Wales, Australia.
Peter GreerDepartment of Radiation Oncology, Calvary Mater Hospital Newcastle, Newcastle, New South Wales, Australia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe aim was to develop and evaluate an EPID-based MLC positional test that addresses known weaknesses of the picket fence test and has sufficient accuracy so that the AAPM MPPG 8.b. MLC position action limit of ± 0.5 mm can be implemented.

methodsWeaknesses and inaccuracies in the picket fence test were identified and a new test plan and analysis algorithm named stakitt was developed. Stakitt was evaluated for repeatability and for sensitivity on the Varian TrueBeam linac with both Millennium MLC and HDMLC and on a Varian Clinac with Millennium MLC. Sensitivity was tested via deliberate introduction of errors into the test plan of magnitude: ± 0.1, ± 0.5, ± 1.0 and ± 1.5 mm. Measured sensitivity was compared to published sensitivity of the picket fence test. Additionally, a use case was presented based on results from a TrueBeam linac to highlight the effect of MLC backlash on MLC positions at non-zero gantry angles.

resultsRepeatability was observed to within 0.04 mm (3 SD) with the TrueBeams being more repeatable than the Clinac. The deliberately introduced errors were accurately measured to within 0.28 mm and were comparable to the traditional picket fence. Reduced accuracy was recorded for the HDMLC small leaves, which was attributed to an apparent variation in measured leaf width across the range of travel, which impacted the measurement of the leaf tip position. The clinical use case demonstrated variability in MLC leaf positions between gantry 90° and gantry 270° that were of the magnitude of the MLC backlash.

conclusionThe stakitt test addresses the weaknesses of the picket fence test and has accuracy appropriate for implementation of a ± 0.5 mm action limit. However, such an action limit may not be currently practical at non-zero gantry angles due to the impact of MLC leaf backlash.

Indexed as

AlgorithmsNeoplasmsParticle AcceleratorsPhantoms, ImagingQuality Assurance, Health CareRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedHumansRadiotherapy Dosage87.55.QrEPIDMLCpicket fencequality assurance (QA)

Identifiers

PMID39611789
PMCPMC11799905

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.