ArticleJournal of applied clinical medical physics2025
Evaluation of an improved picket fence style test for routine MLC positional QA.
Article in Journal of applied clinical medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- Comparison of log file-based and measurement-based QA for detecting MLC positional errors and evaluating dosimetric impacts of MLC defects.Journal of applied clinical medical physics · 2025Article
- A pathway away from measurement-based patient-specific QA: A review of contemporary quality assurance for external-beam radiotherapy sub-systems.Journal of applied clinical medical physics · 2025Review
- A multi-institution performance assessment of a double-layer MLC.Journal of applied clinical medical physics · 2025Article
- Evaluation of the TrueBeam machine-performance-check (MPC): Collimator device check (CDC).Journal of applied clinical medical physics · 2025Article
- Evaluation of an improved picket fence style test for routine MLC positional QA.Journal of applied clinical medical physics · 2025Article
- Comparative Evaluation of Curve-fitting Techniques for Electronic Portal Imaging Device-based Multileaf Collimator Picket Fence Analysis.Journal of medical physicsArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe aim was to develop and evaluate an EPID-based MLC positional test that addresses known weaknesses of the picket fence test and has sufficient accuracy so that the AAPM MPPG 8.b. MLC position action limit of ± 0.5 mm can be implemented.
methodsWeaknesses and inaccuracies in the picket fence test were identified and a new test plan and analysis algorithm named stakitt was developed. Stakitt was evaluated for repeatability and for sensitivity on the Varian TrueBeam linac with both Millennium MLC and HDMLC and on a Varian Clinac with Millennium MLC. Sensitivity was tested via deliberate introduction of errors into the test plan of magnitude: ± 0.1, ± 0.5, ± 1.0 and ± 1.5 mm. Measured sensitivity was compared to published sensitivity of the picket fence test. Additionally, a use case was presented based on results from a TrueBeam linac to highlight the effect of MLC backlash on MLC positions at non-zero gantry angles.
resultsRepeatability was observed to within 0.04 mm (3 SD) with the TrueBeams being more repeatable than the Clinac. The deliberately introduced errors were accurately measured to within 0.28 mm and were comparable to the traditional picket fence. Reduced accuracy was recorded for the HDMLC small leaves, which was attributed to an apparent variation in measured leaf width across the range of travel, which impacted the measurement of the leaf tip position. The clinical use case demonstrated variability in MLC leaf positions between gantry 90° and gantry 270° that were of the magnitude of the MLC backlash.
conclusionThe stakitt test addresses the weaknesses of the picket fence test and has accuracy appropriate for implementation of a ± 0.5 mm action limit. However, such an action limit may not be currently practical at non-zero gantry angles due to the impact of MLC leaf backlash.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.