ArticleJournal of applied clinical medical physics2025
Impact of belly board immobilization devices and body mass factor on setup displacement using daily cone-beam CT in rectal cancer radiotherapy.
Article in Journal of applied clinical medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07676032 (The Impact of Body Composition on Setup Errors in Patients Undergoing Radiotherapy With Thermoplastic Mask Immobilization), which is not on this map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
The Impact of Body Composition on Setup Errors in Patients Undergoing Radiotherapy With Thermoplastic Mask Immobilization: A Single-Center Prospective Cohort Study
Who cites it
4 citing papers in PubMed.
- Surface-Guided Radiotherapy for Vulvar Cancer in the Frog-Leg Position: Setup Accuracy and BMI Effects.Journal of applied clinical medical physics · 2026Article
- Risk stratification and cross-center prediction of thoracoabdominal 6D setup errors.BMC cancer · 2026Article
- Setup Error Differences and Margin Expansion Among Rectal Cancer Segments: Consistency Evaluation Between EPID and iSCOUT.Cancer reports (Hoboken, N.J.) · 2026Article
- Impact of belly board immobilization devices and body mass factor on setup displacement using daily cone-beam CT in rectal cancer radiotherapy.Journal of applied clinical medical physics · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
Abstract
objectiveThe objective of this study is to evaluate the impact of different belly board and daily changes in patient's body-mass factor (BMF) on setup displacement in radiotherapy for rectal cancer.
methodsTwenty-five patients were immobilized using the thermoplastic mask with belly board (TM-BB), and 30 used the vacuum bag cushion with belly board (VBC-BB), performing daily cone-beam computed tomography (CBCT) scans 625 times and 750 times, respectively. Daily pretreatment CBCT scans were registered to the planned CT images for BMF change determination and setup displacement measurement. Independent t-tests compared setup displacement between the two groups in left-right (LR), superior-inferior (SI), and anterior-posterior (AP) directions, as well as the BMF changes. The impact of daily BMF changes on setup displacement was evaluated using multivariate logistic regression and 10-fold cross-validation.
resultsThe setup displacement for TM-BB in the LR, SI, and AP directions were 0.31 ± 0.25, 0.58 ± 0.40, and 0.19 ± 0.18 cm, respectively, while VBC-BB showed 0.19 ± 0.15, 0.26 ± 0.22, and 0.36 ± 0.29 cm in the corresponding directions, respectively. Margins of planning target volume (PTV) for TM-BB were 8, 10, and 6 mm in LR, SI, and AP directions, while VBC-BB showed margins of 5,7, and 8 mm, respectively. The daily BMF changes for both groups were ranked in descending order as follows: sacral rotation angle (RS), hip lateral diameter (HLD), and hip anterior-posterior diameter (HAPD). HAPD was the main factor affecting setup displacement in both the AP and SI directions in TM-BB, while RS was the primary factor for setup displacement in the AP direction in VBC-BB.
conclusionCompared with TM-BB, VBC-BB had a larger AP displacement but smaller in LR and SI displacement. Daily changes in BMF have distinct effects on setup displacement in different immobilization devices. Image-guided radiation therapy (IGRT) is highly recommended and BMF changes should be given consideration during radiotherapy.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials