ArticleJournal of biomedical materials research. Part B, Applied biomaterials2024

Degradation and Fatigue Behavior of 3D-Printed Bioresorbable Tracheal Splints.

Jenna M Wahbeh, John Lama, Sang-Hyun Park, Edward Ebramzadeh, Scott J Hollister, Sophia N Sangiorgio

Abstract read
In one paragraph

Article in Journal of biomedical materials research. Part B, Applied biomaterials, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jenna M WahbehJ. Vernon Luck, Sr., M.D. Orthopaedic Research Center, Luskin Orthopaedic Institute for Children in Alliance With UCLA, Los Angeles, California, USA.ORCID 0000-0003-0101-5645
John LamaJ. Vernon Luck, Sr., M.D. Orthopaedic Research Center, Luskin Orthopaedic Institute for Children in Alliance With UCLA, Los Angeles, California, USA.
Sang-Hyun ParkJ. Vernon Luck, Sr., M.D. Orthopaedic Research Center, Luskin Orthopaedic Institute for Children in Alliance With UCLA, Los Angeles, California, USA.
Edward EbramzadehJ. Vernon Luck, Sr., M.D. Orthopaedic Research Center, Luskin Orthopaedic Institute for Children in Alliance With UCLA, Los Angeles, California, USA.
Scott J HollisterDepartment of Biomedical Engineering, Georgia Institute for Technology, Atlanta, California, USA.
Sophia N SangiorgioJ. Vernon Luck, Sr., M.D. Orthopaedic Research Center, Luskin Orthopaedic Institute for Children in Alliance With UCLA, Los Angeles, California, USA.

Funding

Degradation and Fatigue Behavior of 3D Printed Bioresorbable Tracheal SplintsR01HD086201 · NICHD · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI HOLLISTER, SCOTT J · 2016 to 2020
$2.4M
NICHD NIH HHS R01 HD086201NIH HHS
6 · The paper itself

Abstract

Severe infantile tracheobronchomalacia (TBM) is often treated with invasive surgery and fixed-size implants to support the trachea during respiration. A novel 3D-printed extra-luminal splint has been developed as a flexible and bioresorbable alternative. Therefore, the goal of the present study was to use an in vitro breathing simulator model to comprehensively evaluate the structural stiffness and failure modes of two sizes of a novel bioresorbable 3D-printed splint design under a range of physiological degradation conditions. Two thicknesses, 2 mm and 3 mm, of a novel 3D-printed bioresorbable splint were evaluated under two different degradation conditions, phosphate-buffered saline (PBS) and sodium hydroxide (NaOH). The splints were subjected to simulated breathing loading, involving a cyclic opening and closing of the splint by 2 mm, for a targeted duration of 7.5 to 30 million cycles. A separate new set of splints were statically soaked in their respective degradation condition for a comparative analysis of the effects of cyclic loading by the degradation medium. After successfully simulated breathing or static soaking, non-destructive tensile and compressive strengths were evaluated, and overall stiffness was calculated from destructive tensile testing. The present study indicates that the splints were more significantly degraded under simulated breathing conditions than under soaking. Cyclic simulated breathing specimens failed far earlier than the intended duration of loading. Over time, both 2 mm and 3 mm splints became increasingly more flexible when subjected to the static degradation conditions. Interestingly, there was little difference in the compressive and tensile strengths of the 2 mm and 3 mm thickness splints. The bioresorbable nature of PCL offers a valuable advantage as it eliminates the need for splint removal surgery and increases device flexibility over time with degradation. This increased flexibility is crucial because it allows for uninhibited growth and development of the infant's trachea over the intended use period of 2 years. The results of this study confirm that the splints were able to withstand tensile forces to prevent tracheal collapse. This study further supports the successful use of 3D-printed splints in the treatment of infantile TBM.

Indexed as

Absorbable ImplantsMaterials TestingPrinting, Three-DimensionalSplintsTracheaHumans3D‐printingdegradationfatiguesplintTracheobronchomalacia

Identifiers

PMID39607369
PMCPMC11619926

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.