Evidence map›Paper›PMID 39606132›Full record

ArticleCureus2024

Early Outcome of a Contemporary Unicondylar Knee System.

Kevin B Fricka, Alexander V Strait, Henry Ho, Robert H Hopper, Craig J McAsey

Abstract read
In one paragraph

Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Kevin B FrickaOrthopaedics, Anderson Orthopaedic Clinic, Arlington, USA.
Alexander V StraitAdult Hip and Knee Replacement, Anderson Orthopaedic Research Institute, Alexandria, USA.
Henry HoAdult Hip and Knee Replacement, Anderson Orthopaedic Research Institute, Alexandria, USA.
Robert H HopperAdult Hip and Knee Replacement, Anderson Orthopaedic Research Institute, Alexandria, USA.
Craig J McAseyOrthopaedics, Anderson Orthopaedic Clinic, Arlington, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionIn 2019, a new fixed-bearing implant for unicondylar knee arthroplasty (UKA) was introduced that incorporated a round-on-flat design featuring an Oxinium femoral component coupled with a highly crosslinked polyethylene bearing surface. Compared to prior implants, the design featured smaller size increments coupled with medial and lateral-specific tibial baseplates. The objective of this study is to describe our institution's early experience with this UKA implant system by evaluating survivorship, reasons for revision, and patient-reported outcome measures (PROMs).

methodsThe 944 UKAs that comprise the study population, including 814 medial and 130 lateral joint replacements, were performed by six surgeons from September 2019 through the end of December 2023. All UKA components were cemented, the mean age at surgery was 67.1±10.0 years, 57% (537/944) of the UKAs were performed among women, and the mean body mass index was 30.3±6.2 kg/m

resultsUsing reoperation for any reason as an endpoint, 1-year survivorship was 99.3% (95% CI, 98.7 to 99.9%) and 2-year survivorship was 98.2% (95% CI, 96.9 to 99.5%). There were nine reoperations among the 944 UKAs, including three for infection, two for tibial loosening, one for femoral loosening, one for progression of arthritis, one for patellar instability, and one for recurrent hemarthrosis. The mean time to reoperation was 0.82±0.68 years and all were performed among medial UKAs. Range of motion increased from 117±8 degrees preoperatively to 122±6 degrees at 1-year follow-up. PROMs, including the Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS JR) and the Patient-Reported Outcomes Measurement Information System (PROMIS) Global Health Physical score, demonstrated progressive increases from the preoperative assessment through 2-year follow-up. For UKAs with preoperative and 2-year KOOS JR scores, the mean change was 31±17.

conclusionAs new implants and technologies are introduced, documenting the early outcome from high volume centers can offer valuable insights to validate the effectiveness of implant systems before they are adopted by the broader orthopedic community. This study demonstrates encouraging early outcome data associated with a contemporary UKA system based on survivorship and PROMs. At this early stage, there are no implant-related concerns but obtaining additional follow-up will be important to quantify how revisions and PROMs evolve over time.

Indexed as

journey ii unicondylar kneekaplan-meier survivorshipkoos jrpatient-reported outcome measurespromis global health mentalpromis global health physicalreasons for revision

Identifiers

PMID39606132
PMCPMC11602105

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.