Evidence map›Paper›PMID 39605104›Full record

ArticleKnee surgery & related research2024

A deep learning based automatic two-dimensional digital templating model for total knee arthroplasty.

Jaeseok Park, Sung Eun Kim, Back Kim, Sanggyu Lee, Jae-Jun Lee, Du Hyun Ro

Abstract read
In one paragraph

Article in Knee surgery & related research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jaeseok ParkCollege of Medicine, Seoul National University, Seoul, South Korea.
Sung Eun KimDepartment of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul, South Korea.
Back KimCollege of Medicine, Seoul National University, Seoul, South Korea.
Sanggyu LeeDepartment of Computer Science and Engineering, Seoul National University, Seoul, South Korea.
Jae-Jun LeeDepartment of Orthopaedic Surgery, Seoul National University Hospital, Seoul, South Korea.
Du Hyun RoDepartment of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul, South Korea. duhyunro@gmail.com.ORCID http://orcid.org/0000-0001-6199-908X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPreoperative templating is an important step for total knee arthroplasty (TKA), facilitating hospital personnel in the anticipation and preparation of necessary surgical resources. Despite its importance, this process currently lacks automation. This study aimed to develop an artificial intelligence (AI) model to automate implant size prediction.

methodsA total of 13,281 (2938 anteroposterior, 10,343 lateral) knee radiographs obtained from the authors' institute were utilized for model training, with 2302 (1034 anteroposterior, 1268 lateral) images set apart for validation and testing. The templating AI model integrates a pipeline composed of multiple steps for automated implant size estimation. To predict implant size, anterioposterior (AP) and lateral radiograph predictions were merged, selecting the smaller of the predicted sizes to prevent implant overhang. The model's size predictions were validated with 81 real TKA data set apart from the training data, and its accuracy was compared to that of manual templating by an orthopedic specialist. Predictions matching the actual implanted sizes were labeled "exact" and those within one size, "accurate." The influence of patient characteristics on the model's prediction accuracy was also analyzed. The measurement time elapsed for implant sizing was recorded for both the AI model and the orthopedic specialist. Implant position predicted by the model was validated by comparing insert locations with postoperative images.

resultsCompared with data from 81 actual TKA procedures, the model provided exact predictions for 39.5% of femoral and 43.2% of tibial components. Allowing a one-size margin of error, 88.9% of predictions were deemed "accurate" for both components. Interobserver reliability (Cohen's kappa) were 0.60 and 0.70 for femoral and tibial implants, respectively, both classified as "substantial." The orthopedic specialist produced results accurate within one-size margin of error in 95.1% and 100% of cases for femoral and tibial components, respectively. Interobserver reliability between the orthopedic specialist and ground truth was 0.76 and 0.8 for femoral and tibial components, respectively. The measurement time per case was 48.7 s for the AI model, compared with 97.5 s for the orthopedic specialist. Compared with postoperative radiographs, predicted implant position had an error of less than 4 mm on average.

conclusionsAn AI-based templating tool for TKA was successfully developed, demonstrating satisfactory accuracy and efficiency. Its application could significantly reduce the clinical workload in TKA preparation.

Indexed as

Artificial intelligenceImplant size predictionPreoperative templatingTotal knee arthroplasty

Identifiers

PMID39605104
PMCPMC11600925

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.