Evidence map›Paper›PMID 39605018›Full record

ArticleBiomedical engineering online2024

Optimizing stent retrievers for mechanical enhancement and in vitro testing in acute ischemic stroke models.

Jae-Won Lee, Han-Ki Kim, JinWoo Kim, Hyuk Choi

Abstract read
In one paragraph

Article in Biomedical engineering online, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Jae-Won Lee *Department of Convergence Medicine, College of Medicine, Korea University, Seoul, South Korea.
Han-Ki Kim *Department of Convergence Medicine, College of Medicine, Korea University, Seoul, South Korea.
JinWoo KimDepartment of Bionanosystem Engineering, Graduate School, Jeonbuk National University, Jeonju, South Korea.
Hyuk ChoiDepartment of Convergence Medicine, College of Medicine, Korea University, Seoul, South Korea. hyuk76@korea.ac.kr.

Funding

National Research Foundation of Korea (NRF) grant 2020R1F1A1068910
6 · The paper itself

Abstract

backgroundAcute ischemic stroke (AIS) remains a major cause of morbidity and mortality worldwide. Mechanical thrombectomy, especially with stent retrievers, offers a promising treatment, particularly for patients ineligible for intravenous tissue plasminogen activator (IV tPA) therapy. This study aimed to develop and evaluate novel stent retriever designs to enhance mechanical properties and vessel compatibility.

resultsWe evaluated four stent designs using finite-element analysis (FEA) to assess their mechanical properties. Based on these evaluations, Stent D emerged as the optimal design due to its superior elasticity and adaptability. Comparative testing of Stent D against commercial stents, Solitaire FR and Trevo XP ProVue, revealed the following metrics: radial forces of 3.77 ± 0.01 N for Solitaire FR, 3.92 ± 0.08 N for Trevo XP ProVue, and 4.10 ± 0.07 N for Stent D; flexibility measurements of 0.38 ± 0.11 N for Solitaire FR, 0.91 ± 0.11 N for Trevo XP ProVue, and 0.59 ± 0.05 N for Stent D; deployment forces of 0.37 ± 0.02 N for Solitaire FR, 0.42 ± 0.04 N for Trevo XP ProVue, and 0.32 ± 0.02 N for Stent D; and recapture forces of 0.38 ± 0.01 N for Solitaire FR, 0.45 ± 0.02 N for Trevo XP ProVue, and 0.35 ± 0.01 N for Stent D. Thrombus retrieval rates were 96.16% for Solitaire FR and 95.51% for Stent D.

conclusionsThese findings demonstrate that Stent D performs comparably to commercial stents, highlighting its effective performance in AIS treatment. Stent D shows promise as a candidate for further clinical evaluation due to its superior mechanical properties and effective thrombus retrieval capabilities.

Indexed as

Finite Element AnalysisIschemic StrokeMaterials TestingMechanical PhenomenaStentsHumansThrombectomyAcute ischemic strokeFinite-element analysisPerformance evaluationStent designStent retriever

Identifiers

PMID39605018
PMCPMC11600572

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.