ArticleScientific reports2024
An in vitro biomechanical evaluation of integrated lateral plate combined with oblique lateral interbody fusion in different bone conditions.
Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Are Ceramic Cages an Option for Lumbar Interbody Fusion? A Comparative Biomechanical Numerical Study.JOR spine · 2026Article
- Biomechanical advances in oblique lateral lumbar interbody fusion using different interbody cages.Journal of orthopaedic surgery and research · 2026Review
- Does Anteroposterior Cage Position and Screw Orientation Influence Clinical/Radiographic Outcomes and Complications After Oblique Lumbar Interbody Fusion with Lateral Plate Fixation?Orthopedic research and reviews · 2026Article
- A finite element-based comparative dynamic biomechanical study of a novel oblique lateral locking plate system (OLLPS) versus traditional internal fixations for oblique lumbar interbody fusion (OLIF) under whole-body vibration.Frontiers in bioengineering and biotechnology · 2026Article
- Biomechanical evaluation of a novel L-shaped side-locking plate combined with OLIF: a finite element analysis considering 3 different bone densities.Frontiers in surgery · 2026Article
- Biomechanical changes of different cement volumes at the thoracolumbar vertebrae in osteoporotic compression fractures: a finite element analysis.BMC musculoskeletal disorders · 2025Article
- Oblique lumbar interbody fusion-address to an anatomical challenge: a case report.Frontiers in surgery · 2025Article
- A rapid method for the preparation of anFrontiers in bioengineering and biotechnology · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
Oblique lateral interbody fusion (OLIF) is a minimally invasive surgery for the treatment of lumbar degenerative diseases (LDD). Under normal bone mass(NB), supplemental with lateral plate (LP) fixation has been proven to provide stability and reduce complications. However, it is unclear whether OLIF combined with LP fixation can achieve satisfactory fixation effects in cases of osteoporosis(OP) or osteopenia (OS)? In this study, Eighteen L3-5 spinal specimens from 3 to 6 months old fresh calves were equally divided into 3 groups: group A (NB), group B (OS) and group C (OP). A load control scheme was adopted and evaluated using multidirectional nondestructive moments (± 7.5 N·m). An electronic universal tester and a tensile/torsion tester were simulated to generate 6 degrees of freedom of motion, and a VIC-3D three-dimensional optical full-field strain measurement system dynamically tracked the surgical segmental displacement. Each spine was evaluated under the following conditions at the L4-5 level: intact (INT); OLIF stand-alone (SA); cage supplemented with LP, cage supplemented with unilateral pedicle screws (UPS), and cage supplemented with bilateral pedicle screws (BPS). The current data show that With NB and OS models, LP fixation significantly reduced ROM in the LB and AR directions, with slightly less stability than BPS fixation and comparable to UPS. In the case of OP, LP fixation may increase the risk of internal fixation failure, and it is more preferable to choose BPS fixation with stronger stability.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.