Evidence map›Paper›PMID 39599122›Full record

ArticleSensors (Basel, Switzerland)2024

Automatic Image Registration Provides Superior Accuracy Compared with Surface Matching in Cranial Navigation.

Henrik Frisk, Margret Jensdottir, Luisa Coronado, Markus Conrad, Susanne Hager, Lisa Arvidsson, Jiri Bartek, Gustav Burström, Victor Gabriel El-Hajj, Erik Edström and 2 more

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Henrik FriskDepartment of Clinical Neuroscience, Karolinska Institutet, SE 17177 Stockholm, Sweden.ORCID 0000-0001-7317-1554
Margret JensdottirDepartment of Clinical Neuroscience, Karolinska Institutet, SE 17177 Stockholm, Sweden.
Luisa CoronadoClinical Affairs, Brainlab AG, 81829 Munich, Germany.
Markus ConradClinical Affairs, Brainlab AG, 81829 Munich, Germany.
Susanne HagerClinical Affairs, Brainlab AG, 81829 Munich, Germany.
Lisa ArvidssonDepartment of Clinical Neuroscience, Karolinska Institutet, SE 17177 Stockholm, Sweden.
Jiri BartekDepartment of Clinical Neuroscience, Karolinska Institutet, SE 17177 Stockholm, Sweden.
Gustav BurströmDepartment of Clinical Neuroscience, Karolinska Institutet, SE 17177 Stockholm, Sweden.
Victor Gabriel El-HajjDepartment of Clinical Neuroscience, Karolinska Institutet, SE 17177 Stockholm, Sweden.ORCID 0000-0001-9479-761X
Erik EdströmDepartment of Clinical Neuroscience, Karolinska Institutet, SE 17177 Stockholm, Sweden.ORCID 0000-0002-8781-1169
Adrian Elmi-TeranderDepartment of Clinical Neuroscience, Karolinska Institutet, SE 17177 Stockholm, Sweden.ORCID 0000-0002-3776-6136
Oscar PerssonDepartment of Clinical Neuroscience, Karolinska Institutet, SE 17177 Stockholm, Sweden.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThe precision of neuronavigation systems relies on the correct registration of the patient's position in space and aligning it with radiological 3D imaging data. Registration is usually performed by the acquisition of anatomical landmarks or surface matching based on facial features. Another possibility is automatic image registration using intraoperative imaging. This could provide better accuracy, especially in rotated or prone positions where the other methods may be difficult to perform. The aim of this study was to validate automatic image registration (AIR) using intraoperative cone-beam computed tomography (CBCT) for cranial neurosurgical procedures and compare the registration accuracy to the traditional surface matching (SM) registration method based on preoperative MRI. The preservation of navigation accuracy throughout the surgery was also investigated.

methodsAdult patients undergoing intracranial tumor surgery were enrolled after consent. A standard SM registration was performed, and reference points were acquired. An AIR was then performed, and the same reference points were acquired again. Accuracy was calculated based on the referenced and acquired coordinates of the points for each registration method. The reference points were acquired before and after draping and at the end of the procedure to assess the persistency of accuracy.

resultsIn total, 22 patients were included. The mean accuracy was 6.6 ± 3.1 mm for SM registration and 1.0 ± 0.3 mm for AIR. The AIR was superior to the SM registration (

conclusionsAIR for cranial neuronavigation consistently delivered greater accuracy than SM and should be considered the new gold standard for patient registration in cranial neuronavigation. If intraoperative imaging is a limited resource, AIR should be prioritized in rotated or prone position procedures, where the benefits are the greatest.

Indexed as

Cone-Beam Computed TomographyImaging, Three-DimensionalMagnetic Resonance ImagingNeuronavigationAdultAgedBrain NeoplasmsFemaleHumansImage Processing, Computer-AssistedMaleMiddle AgedNeurosurgical ProceduresSkullSurgery, Computer-Assistedaccuracyautomatic image registrationCBCTneurosurgerypatient trackingreference framesurface matchingsurgical navigation

Identifiers

PMID39599122
PMCPMC11597983

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.