Evidence map›Paper›PMID 39599079›Full record

ArticleSensors (Basel, Switzerland)2024

Location Method of Buried Polyethylene Gas Pipeline Based on Acoustic Signal Ellipse Method.

Hanyu Zhang, Yang Li, Zhuo Xu, Ao Zhang, Xianfa Liu, Pengyao Sun, Xianchao Sun

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Hanyu ZhangSchool of Mechanical Engineering, Northeast Electric Power University, Jilin 132011, China.
Yang LiSchool of Mechanical Engineering, Northeast Electric Power University, Jilin 132011, China.
Zhuo XuSchool of Mechanical Engineering, Northeast Electric Power University, Jilin 132011, China.
Ao ZhangSchool of Mechanical Engineering, Shenyang Jianzhu University, Shenyang 110168, China.ORCID 0000-0001-7713-2050
Xianfa LiuHunan Anguang Inspection and Testing Company, Changde 415131, China.
Pengyao SunSpecial Equipment Inspection Center of Jilin, Special Equipment Accident Investigation Service Center of Jilin, Jilin 132089, China.
Xianchao SunChangchun Special Equipment Inspection & Research Institute (Changchun Special Equipment Safety Monitoring Center), Changchun 130013, China.

Funding

Key Research and Development Project Science and Technology Agency of Jilin Province 20230203155SF
6 · The paper itself

Abstract

This study proposes a buried PE gas pipeline positioning method based on the elliptical method of an acoustic signal analysis. The cross-correlation time delay positioning technology is combined with the elliptical equation, forming an effective mechanism for pipeline depth positioning. First, a dual-tree complex wavelet transform is employed to denoise the collected signals, enhancing the quality and accuracy of the data. Subsequently, the cross-correlation function is utilized to extract the delay times between the signals. The obtained delay times are then substituted into the elliptical equation to calculate the depth of the buried PE pipeline. Based on this theoretical framework, a simulation model is established in COMSOL, and positioning simulation analyses are conducted under three different conditions: pipeline depth, relative sensor positions, and distances between sensors and excitation points. The simulation results indicate that a clear correlation exists between the signal delay time and the pipeline position, with simulation errors controlled within 5%, thus validating the theoretical feasibility of the method. To further assess the effectiveness of this approach, an experimental testing system is constructed. The experimental study was carried out under four different conditions: pipeline burial depth, relative sensor positions, distances between sensors and excitation points, and excitation frequencies. The experimental results demonstrate that these factors significantly affect the pipeline depth positioning. The comparison results show that the method has a high accuracy in depth positioning, with experimental errors controlled within 10%. This study proves that accurate positioning of pipeline depth could be achieved by substituting signal delay times into the elliptical equation, thereby validating the method's feasibility in practical applications. The proposed method effectively addressed the shortcomings of existing pipeline depth positioning technologies, providing important theoretical support and a practical reference for future pipeline positioning research.

Indexed as

buried PE pipelineCOMSOL simulation depth positioningcross-correlation delay timeelliptic equation localization

Identifiers

PMID39599079
PMCPMC11598132

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.