ArticleSensors (Basel, Switzerland)2024
Development of a DualEmission Laser-Induced Fluorescence (DELIF) Method for Long-Term Temperature Measurements.
Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
The fluorescence intensity of fluorescent dyes typically employed in the dual-emission laser-induced fluorescence (DELIF) method gradually degrades as the excitation time increases, and the degradation rate depends on the type of fluorescent dye used. Therefore, the DELIF method is unsuitable for long-term temperature measurements. In this study, we focused on the fluorescence intensity ratio of a single fluorescent dye at two fluorescence wavelengths and developed a DELIF method for long-term temperature measurements based on this ratio. The fluorescence intensity characteristics of Fluorescein disodium and Rhodamine B, which are typically used in the DELIF method, in the temperature range of 10-60 °C were comprehensively investigated using two high-speed monochrome complementary metal-oxide semiconductor cameras and narrow bandpass filters. Interestingly, the ratio of the fluorescence intensity of each fluorescent dye at the peak emission wavelength of the fluorescence spectrum, λ, to the fluorescence intensity at wavelengths very close to the peak wavelength (λ ± 10 nm) was highly sensitive to temperature variations but not excitation time. Particularly, when Rhodamine B was used, the selection of the fluorescence intensity ratios at a wavelength combination of 589 and 600 nm enabled highly accurate temperature measurements with a temperature resolution of ≤0.042 °C. Moreover, the fluorescence intensity ratio varied negligibly throughout the excitation time of 180 min, with a measurement uncertainty (95% confidence interval) of 0.045 °C at 20 °C. The results demonstrate that the proposed DELIF method enables highly accurate long-term temperature measurements.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.