Evidence map›Paper›PMID 39598879›Full record

ArticleSensors (Basel, Switzerland)2024

Noninvasive Early Detection of Systemic Inflammatory Response Syndrome of COVID-19 Inpatients Using a Piezoelectric Respiratory Rates Sensor.

Tsuyoshi Kobayashi, Takemi Matsui, Isamu Sugita, Norihiro Tateda, Shohei Sato, Kenichi Hashimoto, Masei Suda

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Tsuyoshi KobayashiGraduate School of Systems Design, Tokyo Metropolitan University, Tokyo 191-0065, Japan.ORCID 0009-0005-4120-4098
Takemi MatsuiGraduate School of Systems Design, Tokyo Metropolitan University, Tokyo 191-0065, Japan.ORCID 0000-0002-7309-2271
Isamu SugitaDepartment of Rehabilitation, Suwa Central Hospital, Nagano 391-8503, Japan.
Norihiro TatedaKonica Minolta, Inc., Tokyo 192-8505, Japan.
Shohei SatoGraduate School of Systems Design, Tokyo Metropolitan University, Tokyo 191-0065, Japan.
Kenichi HashimotoDepartment of General Medicine, National Defense Medical College, Saitama 359-8513, Japan.ORCID 0000-0001-6838-1215
Masei SudaDepartment of Rheumatology, Suwa Central Hospital, Nagano 391-0011, Japan.ORCID 0000-0002-2036-6216

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In 2020, 20% of patients with COVID-19 developed severe complications, including life-threatening pneumonia with systemic inflammatory response syndrome (SIRS). We developed a preliminary SIRS monitor that does not require blood sampling, is noninvasive, and can collect data 24 h per day. The proposed monitor comprises a piezoelectric respiratory sensor located beneath the patient's mattress and a fingertip pulse sensor that determines ultra-high accuracy respiratory rate (mode of a 40-min frequency distribution of respiratory rates (M40FD-RR)). We assessed the clinical performance of the M40FD-RR preliminary SIRS monitor in 29 patients (12 female, 17 male, aged 15-90 years) hospitalized at Suwa Central Hospital with COVID-19, which was confirmed by a positive polymerase chain reaction test. SIRS was evaluated by logistic regression analysis using M40FD-RR, heart rate, age, and sex as explanatory variables. We compared the results of 109 examinations of 29 COVID-19 inpatients with SIRS against those determined by the proposed monitor. The proposed monitor achieved 75% sensitivity and 83% negative predictive value, making it a promising candidate for future 24 h noninvasive preliminary SIRS tests.

Indexed as

COVID-19Respiratory RateSARS-CoV-2Systemic Inflammatory Response SyndromeAdolescentAdultAgedAged, 80 and overEarly DiagnosisFemaleHumansInpatientsMaleMiddle AgedMonitoring, PhysiologicYoung AdultCOVID-19noninvasivepiezoelectric respiratory sensorrespiratory ratesystemic inflammatory respiratory syndromewithout blood sampling

Identifiers

PMID39598879
PMCPMC11598245

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.