ArticleMicromachines2024
Design, Testing, and Validation of a Soft Robotic Sensor Array Integrated with Flexible Electronics for Mapping Cardiac Arrhythmias.
Article in Micromachines, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Advanced Robotics for the Next-Generation of Cardiac Interventions.Micromachines · 2025Review
- Design, Fabrication, and Application of Large-Area Flexible Pressure and Strain Sensor Arrays: A Review.Micromachines · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
Abstract
Cardiac mapping is a crucial procedure for diagnosing and treating cardiac arrhythmias. Still, current clinical techniques face limitations including insufficient electrode coverage, poor conformability to complex heart chamber geometries, and high costs. This study explores the design, testing, and validation of a 64-electrode soft robotic catheter that addresses these challenges in cardiac mapping. A dual-layer flexible printed circuit board (PCB) was designed and integrated with sensors into a soft robotic sensor array (SRSA) assembly. Design considerations included flex PCB layout, routing, integration, conformity to heart chambers, sensor placement, and catheter durability. Rigorous SRSA in vitro testing evaluated the burst/leakage pressure, block force for electrode contact, mechanical integrity, and environmental resilience. For in vivo validation, a porcine model was used to demonstrate the successful deployment, conformability, and acquisition of electrograms in both the ventricles and atria. This catheter-deployable SRSA represents a meaningful step towards translating the integration of soft robotic actuators and stretchable electronics for clinical use, showcasing the unique mechanical and electrical performance that these designs enable. The high-density electrode array enabled rapid 2 s data acquisition with detailed spatial and temporal resolution, as illustrated by the clear and consistent cardiac signals recorded across all electrodes. The future of this work will lie in enabling high-density, anatomically conformable devices for detailed cardiac mapping to guide ablation therapy and other interventions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.