ArticleMicromachines2024

Proposal of a Rapid Detection System Using Image Analysis for ELISA with an Autonomous Centrifugal Microfluidic System.

Shunya Okamoto, Yuto Mori, Shota Nakamura, Yusuke Kanai, Yoshiaki Ukita, Moeto Nagai, Takayuki Shibata

Abstract read
In one paragraph

Article in Micromachines, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Shunya OkamotoDepartment of Mechanical Engineering, Toyohashi University of Technology, Toyohashi 441-8122, Japan.ORCID 0000-0003-0762-9197
Yuto MoriDepartment of Mechanical Engineering, Toyohashi University of Technology, Toyohashi 441-8122, Japan.
Shota NakamuraDepartment of Mechanical Engineering, Toyohashi University of Technology, Toyohashi 441-8122, Japan.
Yusuke KanaiDepartment of Mechanical Engineering, Toyohashi University of Technology, Toyohashi 441-8122, Japan.
Yoshiaki UkitaGraduate Faculty of Interdisciplinary Research, University of Yamanashi, Kofu 400-0016, Japan.
Moeto NagaiInstitute for Research on Next-Generation Semiconductor and Sensing Science (IRES2), Toyohashi University of Technology, Toyohashi 441-8122, Japan.ORCID 0000-0002-7852-7772
Takayuki ShibataDepartment of Mechanical Engineering, Toyohashi University of Technology, Toyohashi 441-8122, Japan.ORCID 0000-0003-0972-2950

Funding

JKA Foundation 2024M-561
6 · The paper itself

Abstract

In this study, with the aim of adapting an enzyme-linked immunosorbent assay (ELISA) system for point-of-care testing (POCT), we propose an image analysis method for ELISAs using a centrifugal microfluidic device that automatically executes the assay. The developed image analysis method can be used to quantify the color development reaction on a TMB (3,3',5,5'-tetramethylbenzidine) substrate. In a conventional ELISA, reaction stopping reagents are required at the end of the TMB reaction. In contrast, the developed image analysis method can analyze color in the color-developing reaction without a reaction stopping reagent. This contributes to a reduction in total assay time. The microfluidic devices used in this study could execute reagent control for ELISAs by steady rotation. In the demonstration of the assay and image analysis, a calibration curve for mouse IgG detection was successfully prepared, and it was confirmed that the image analysis method had the same performance as the conventional analysis method. Moreover, the changes in the amount of color over time confirmed that a calibration curve equal to the endpoint analysis was obtained within 2 min from the start of the TMB reaction. As the assay time before the TMB reaction was approximately 7.5 min, the developed ELISA system could detect TMB in just 10 min. In conventional methods using a plate reader, the assay required a time of 90 min for manual handling using microwell plates, and in the case of using automatic microfluidic devices, 30 min were required. The time of 10 min realized by this proposed method is equal to the time required for detection in an immunochromatographic assay with a lateral flow assay; therefore, it is expected that ELISAs can be performed sufficiently to adapt to POCT.

Indexed as

centrifugal microfluidicsELISAPOCT

Identifiers

PMID39597199
PMCPMC11596746

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.