Evidence map›Paper›PMID 39597190›Full record

ArticleMicromachines2024

Analysis of the Radial Force of a Piezoelectric Actuator with Interdigitated Spiral Electrodes.

Yateng Wang, Tianxing Ren, Yuan Ren, Ruijie Gu, Yonggang Liu

Abstract read
In one paragraph

Article in Micromachines, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Yateng WangSchool of Mechatronics Engineering, Henan University of Science and Technology, Luoyang 471003, China.
Tianxing RenSchool of Mechatronics Engineering, Henan University of Science and Technology, Luoyang 471003, China.
Yuan RenSchool of Mechatronics Engineering, Henan University of Science and Technology, Luoyang 471003, China.
Ruijie GuSchool of Mechatronics Engineering, Henan University of Science and Technology, Luoyang 471003, China.
Yonggang LiuSchool of Mechatronics Engineering, Henan University of Science and Technology, Luoyang 471003, China.ORCID 0000-0001-6731-773X

Funding

Key Scientific and Technological Project of Henan Province 225101610004National Natural Science Foundation of China 50975079
6 · The paper itself

Abstract

The actuator is a critical component of the micromanipulator. By utilizing the properties of expansion and contraction, the piezoelectric actuator enables the manipulator to handle and grasp miniature objects during micromanipulation. However, in piezoelectric ceramic disc actuators with conventional surface electrode configurations, the actuating force generated in the radial direction is relatively limited. When used as the actuation element of the manipulator, achieving regulation over a wide range of operating strokes becomes challenging. Therefore, altering the electrode structure is necessary to generate a greater radial force, thus enhancing the positioning and grasping capabilities of the operating arm. This paper investigates a piezoelectric actuator with interdigitated spiral electrodes, featuring a constant pitch between adjacent electrodes. The radial force was tested under mechanical clamping conditions, and the influence of the electrical signal was examined. The characteristics of the electrode structure were described, and the working principles of the piezoelectric actuators were analyzed. Theoretical equations were derived for the macroscopic characterization of the radial clamping force of the actuator, based on the piezoelectric constitutive equation, geometric principles, and Bond matrix transformation relationships. A finite element model was developed, reflecting the features of the electrode structure, and finite element simulations were employed to verify the theoretical equations for radial force. To prepare the samples, encircled interdigitated spiral electrode lines were printed on the PZT-52 piezoelectric ceramic disc using a screen printing method. The clamping force experimental platform was established, and experiments on the clamping radial force were conducted with electrical signals of varying waveforms, frequencies, and voltages. The experimental results show that the piezoelectric ceramic disc actuator with an interdigitated spiral electrode line structure, when excited by a stable sine wave operating at 200 V and 0.2 Hz, generated a peak force of 0.37 N. It was 1.76 times greater than that produced by a previously utilized piezoelectric disc with conventional electrode structures.

Indexed as

electric signalinterdigital spiral electrodepiezoelectric actuatorradial force

Identifiers

PMID39597190
PMCPMC11596320

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.