ArticleMicromachines2024
Design and Investigation of a High-Performance Quartz-Based SAW Temperature Sensor.
Article in Micromachines, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- SAW-Based Hydrogen Sensing: Mechanisms, Design Strategies, and Future Prospects.Micromachines · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In this work, a surface acoustic wave (SAW) temperature sensor based on a quartz substrate was designed and investigated. Employing the Coupling-of-Modes (COM) model, a detailed analysis was conducted on the effects of the number of interdigital transducers (IDTs), the number of reflectors, and their spacing on the performance of the SAW device. The impact of the transversal mode of quartz SAWs on the device was subsequently examined using the finite element method (FEM). The simulation results indicate that optimizing these structural parameters significantly enhances the sensor's sensitivity and frequency stability. SAW devices with optimal structural parameters were fabricated, and their resonant frequencies were tested across a temperature range of 25-150 °C. Experimental results demonstrate that the SAW temperature sensor maintains high performance stability and data reliability throughout the entire temperature range, achieving a Bode-Q of 7700. Furthermore, the sensor exhibits excellent linearity and repeatability. An analysis of the sensor's response under varying temperature conditions reveals a significant temperature dependency on its Temperature Coefficient of Frequency (TCF). This feature suggests that the sensor possesses potential advantages for applications in industrial process control and environmental monitoring.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.