ArticleMicromachines2024
Silicon Microthermocycler for Point-of-Care Analytical Systems: Modeling, Design, and Fabrication.
Article in Micromachines, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
A four-tether silicon microthermocycler for point-of-care PCR analytical systems is proposed. Substituting the commonly employed platinum with titanium in the fabrication of thin film resistance temperature detectors and heaters enabled the realization of a smaller device without compromising temperature accuracy or increasing heater lead power losses. The device was extensively analyzed through analytical modeling and FEM numerical simulations using a 3-D thermo-mechanical simulation model in COMSOL. Numerical simulations revealed that the four-tether design provides a 460% improvement in mechanical strength and a 57% reduction in the thermal time constant compared with a similar three-tether design, with a trade-off of a 22% increase in heat losses. Detailed structural and thermal analyses of crucial design parameters guided the optimization of the final geometry, leading to the successful fabrication of prototypes. It was shown that the current of 60 mA was sufficient to heat the fabricated solid and hollow silicon structure to 132 °C and 134 °C in 10 s for an applied heater power of 510 mW and 525 mW, respectively.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.