ArticleBioengineering (Basel, Switzerland)2024
Unbiased Method to Determine Articular Cartilage Thickness Using a Three-Dimensional Model Derived from Laser Scanning: Demonstration on the Distal Femur.
Article in Bioengineering (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Measuring articular cartilage thickness from 3D models developed from laser scans has the potential to offer high accuracy. However, this potential has not been fulfilled, since generating these models requires that the cartilage be removed, and previous methods of removal have led to systematic errors (i.e., bias) due to changes in the overall dimensions of the underlying bone. The objectives were to present a new method for removing articular cartilage, quantify the bias error, and demonstrate the method on the distal (i.e., 0° flexion) and posterior (i.e., 90° flexion) articular surfaces of example human femurs. The method consisted of creating a 3D articular cartilage model from high-accuracy (i.e., precision = 0.087 mm) laser scans before and after cartilage removal using dermestid beetles to remove the cartilage. Fiducial markers were used to minimize errors in registering surfaces generated from the two laser scans. To demonstrate the method, the cartilage thickness was computed in distal and posterior subregions of each femoral condyle for three example cadaveric specimens. The use of dermestid beetles did not introduce measurable bias, and the previously reported precision achieved in 3D cartilage models with the laser scanner was 0.13 mm. For the different subregions, the cartilage thickness ranged from 1.5 mm to 2.0 mm. A method of imaging by means of laser scanning, cartilage removal by means of dermestid beetles, and 3D model registration by means of fiducial markers ensured that cartilage thickness on the articular surface of the long bones of the knee was determined with negligible bias and a precision of 0.13 mm. With this method, the potential to measure cartilage thickness with high accuracy based on 3D models developed from laser scans can be fully realized.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.