Evidence map›Paper›PMID 39593764›Full record

ArticleBioengineering (Basel, Switzerland)2024

Enhancing Aerosol Mitigation in Medical Procedures: A CFD-Informed Respiratory Barrier Enclosure.

Ju Young Hong, Seungcheol Ko, Ki Sub Sung, Min Jae Oh, Min Ji Kim, Jung Woo Lee, Yoo Seok Park, Yong Hyun Kim, Joon Sang Lee

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Ju Young HongEmergency Medicine, Yonsei University College of Medicine, Seoul 03722, Republic of Korea.ORCID 0000-0003-3416-3054
Seungcheol KoSchool of Mechanical Engineering, Yonsei University, Seoul 03722, Republic of Korea.
Ki Sub SungSS-ENG Co., Ltd., Bucheon 14449, Republic of Korea.
Min Jae OhAI & Energy Research Center, Korea Photonics Technology Institute, Gwangju 61007, Republic of Korea.
Min Ji KimEmergency Medicine, Yonsei University College of Medicine, Seoul 03722, Republic of Korea.
Jung Woo LeeSchool of Mechanical Engineering, Yonsei University, Seoul 03722, Republic of Korea.
Yoo Seok ParkEmergency Medicine, Yonsei University College of Medicine, Seoul 03722, Republic of Korea.
Yong Hyun KimAI & Energy Research Center, Korea Photonics Technology Institute, Gwangju 61007, Republic of Korea.
Joon Sang LeeSchool of Mechanical Engineering, Yonsei University, Seoul 03722, Republic of Korea.

Funding

Ministry of Health & Welfare, Republic of Korea RS-2022-KH124483
6 · The paper itself

Abstract

The COVID-19 pandemic has highlighted the significant infection risks posed by aerosol-generating procedures (AGPs), such as intubation and cardiopulmonary resuscitation (CPR). Despite existing protective measures, high-risk environments like these require more effective safety solutions. In response, our research team has focused on developing a novel respiratory barrier enclosure designed to enhance the safety of healthcare workers and patients during AGPs. We developed a hood that covers the patient's respiratory area, incorporating a negative pressure system to contain aerosols. Using computational fluid dynamics (CFD) analysis, we optimized the hood's design and adjusted the negative pressure levels based on simulations of droplet dispersion. To test the design, Polyalphaolefin (PAO) particles were generated inside the hood, and leakage was measured every 10 s for 90 s. The open side of the hood was divided into nine sections for consistent leakage measurements, and a standardized structure was implemented to ensure accuracy. Our target was to maintain a leakage rate of less than 0.3%, in line with established filter-testing criteria. Through iterative improvements based on leakage rates and intubation efficiency, we achieved significant results. Despite reducing the hood's size, the redesigned enclosure showed a 36.2% reduction in leakage rates and an approximately 3204.6% increase in aerosol extraction efficiency in simulations. The modified hood, even in an open configuration, maintained a droplet leakage rate of less than 0.3%. These findings demonstrate the potential of a CFD-guided design in developing respiratory barriers that effectively reduce aerosol transmission risks during high-risk medical procedures. This approach not only improves the safety of both patients and healthcare providers but also provides a scalable solution for safer execution of AGPs in various healthcare settings.

Indexed as

aerosol transmissioncomputational fluid dynamicintubationrespiratory infection

Identifiers

PMID39593764
PMCPMC11591818

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.