Evidence map›Paper›PMID 39593196›Full record

ArticleEuropean journal of medical research2024

New technology: clinical efficacy of intracapsular decompression and supported hollow screw treatment for Garden IV femoral neck fractures.

Zhaofeng Jia, Tinghui Xiao, Yimiao Lin, Wenjun Huang, Peizhi Deng, Jiandong Lin, Shiyuan Lin, Jiwu Cheng, Fengting Cui, Xinjia Hu and 1 more

Abstract read
In one paragraph

Article in European journal of medical research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Treatment-center variations in open versus closed reduction for nonelderly femoral neck fractures.OTA international : the open access journal of orthopaedic trauma · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Zhaofeng JiaDepartment of Traumatic Orthopedics and Institute of Orthopedic Research, Shenzhen People's Hospital, The Second Clinical Medical College of Jinan University and the First Affiliated Hospital of Southern University of Science and Technology, Shenzhen, 518035, Guangdong, China.
Tinghui XiaoDepartment of Traumatic Orthopedics and Institute of Orthopedic Research, Shenzhen People's Hospital, The Second Clinical Medical College of Jinan University and the First Affiliated Hospital of Southern University of Science and Technology, Shenzhen, 518035, Guangdong, China.
Yimiao LinDepartment of Traumatic Orthopedics and Institute of Orthopedic Research, Shenzhen People's Hospital, The Second Clinical Medical College of Jinan University and the First Affiliated Hospital of Southern University of Science and Technology, Shenzhen, 518035, Guangdong, China.
Wenjun HuangDepartment of Traumatic Orthopedics and Institute of Orthopedic Research, Shenzhen People's Hospital, The Second Clinical Medical College of Jinan University and the First Affiliated Hospital of Southern University of Science and Technology, Shenzhen, 518035, Guangdong, China.
Peizhi DengDepartment of Traumatic Orthopedics and Institute of Orthopedic Research, Shenzhen People's Hospital, The Second Clinical Medical College of Jinan University and the First Affiliated Hospital of Southern University of Science and Technology, Shenzhen, 518035, Guangdong, China.
Jiandong LinDepartment of Traumatic Orthopedics and Institute of Orthopedic Research, Shenzhen People's Hospital, The Second Clinical Medical College of Jinan University and the First Affiliated Hospital of Southern University of Science and Technology, Shenzhen, 518035, Guangdong, China.
Shiyuan LinDepartment of Traumatic Orthopedics and Institute of Orthopedic Research, Shenzhen People's Hospital, The Second Clinical Medical College of Jinan University and the First Affiliated Hospital of Southern University of Science and Technology, Shenzhen, 518035, Guangdong, China.
Jiwu ChengDepartment of Traumatic Orthopedics and Institute of Orthopedic Research, Shenzhen People's Hospital, The Second Clinical Medical College of Jinan University and the First Affiliated Hospital of Southern University of Science and Technology, Shenzhen, 518035, Guangdong, China.
Fengting CuiDepartment of Traumatic Orthopedics and Institute of Orthopedic Research, Shenzhen People's Hospital, The Second Clinical Medical College of Jinan University and the First Affiliated Hospital of Southern University of Science and Technology, Shenzhen, 518035, Guangdong, China.
Xinjia HuDepartment of Traumatic Orthopedics and Institute of Orthopedic Research, Shenzhen People's Hospital, The Second Clinical Medical College of Jinan University and the First Affiliated Hospital of Southern University of Science and Technology, Shenzhen, 518035, Guangdong, China.
Xiaoming ZhangDepartment of Traumatic Orthopedics and Institute of Orthopedic Research, Shenzhen People's Hospital, The Second Clinical Medical College of Jinan University and the First Affiliated Hospital of Southern University of Science and Technology, Shenzhen, 518035, Guangdong, China. zxx818788@163.com.

Funding

Heyuan City Social Development Science and Technology Plan Project 230613171602486Shenzhen Science and Technology Projects JCYJ20190806160014794Shenzhen Science and Technology Projects JCYJ20220530152213030Shenzhen Science and Technology Projects JCYJ20220530152214032
6 · The paper itself

Abstract

backgroundThe management of Garden IV femoral neck fractures presents a formidable challenge. This study aimed to assess the safety and efficacy of a novel technological approach for treating Garden IV femoral neck fractures, involving intracapsular decompression and the utilization of supported hollow screws.

methodsBetween October 2018 and October 2021, a cohort of 46 patients, comprising 25 males and 21 females, was admitted for Garden IV femoral neck fractures. The surgical intervention employed a novel methodology, involving closed reduction of femoral neck fractures on a traction bed and percutaneous implantation of decompression support hollow screw internal fixation in the capsule. Operative parameters such as intraoperative bleeding volume, incision length, and fluoroscopy frequency were recorded. Postoperative angiography was performed to evaluate the blood supply to the femoral neck and femoral head, while long-term follow-up records documented femoral neck fracture healing and patient functional recovery.

resultsThe closed reduction and minimally invasive implantation of decompression support screws in the femoral neck capsule proved effective in successfully fixing Garden IV femoral neck fractures. The screw placement time was 20-45 min, with an average of 25.2 min. The number of fluoroscopy was 6-14, with an average of 7. The postoperative follow-up was 20-25 months, with an average duration of 22 months. All patients exhibited uneventful single-stage wound healing, devoid of complications such as nerve, blood vessel, or important tissue structure injuries. While femoral head necrosis occurred in one case and femoral neck shortening in another, all femoral neck fractures exhibited healing. Post-surgery, patients experienced rapid recovery, enabling early functional exercise with satisfactory functional restoration.

conclusionThe innovative technology, employing femoral neck capsule decompression support hollow screws, not only offers structural support, but also facilitates capsule decompression post-femoral neck fracture surgery. This approach promotes the restoration of blood flow to the femoral head and neck, accelerates fracture healing, diminishes the likelihood of femoral head necrosis, and enhances the overall therapeutic outcome for Garden IV femoral neck fractures. The merits of this novel technique warrant its widespread adoption and application.

Indexed as

Bone ScrewsDecompression, SurgicalFemoral Neck FracturesFracture Fixation, InternalAdultAgedFemaleHumansMaleMiddle AgedTreatment OutcomeFemoral neck fractureGarden IVIntracapsular decompression and supported hollow screwMinimally invasive percutaneous treatment

Identifiers

PMID39593196
PMCPMC11600569

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.