ArticleBMC pregnancy and childbirth2024
Bladder involvement in placenta accreta spectrum disorders: 2D US combined with the 3D crystal Vue and MRI comparative analysis.
Article in BMC pregnancy and childbirth, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Risk factors and clinical characteristics of pernicious placenta accreta in pregnancies complicated by placenta previa.Medicine · 2026Article
- Crystal Vue-Estimated placental invasion area as a novel predictor of postpartum hemorrhage risk in placenta accreta spectrum disorders: a retrospective cohort study.BMC pregnancy and childbirth · 2026Article
- Maternal and Clinical Outcomes of Placenta Accreta Spectrum: Insights from a Retrospective Study in Bahrain.Life (Basel, Switzerland) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
Abstract
backgroundPlacental accreta spectrum (PAS) disorder with bladder involvement is found to be associated with severe maternal and neonatal morbidity.When planning surgery or other treatments, a diagnosis and assessment of the invasiveness of placenta accreta spectrum disorder with bladder involvement are crucial.The detection of the depth of villi invasion can be accomplished with both MRI and US.The advent of three-dimensional Crystal Vue provides details additional information for scanning abnorma issue. PURPOSE: Our goal was to compare and assess the diagnostic accuracy of 2D US combined with the 3D Crystal Vue and MRI in case of placenta accreta spectrum (PAS) involving the bladder. MATERIALS AND
methods111 pregnancy patients between May 2019 and November 2023 at the First Affiliated Hospital of Anhui Medical University whether or not they had placenta previa were included in the study if they were diagnosed of having placenta increta (PI) or placenta percreta (PP).Both US and MRI were used to evaluate the pregnant women.Total 53 pregnant women were ultimately included in our analysis.53 patients were split into groups with and without bladder involvement. They underwent 2D US,3D Crystal Vue, and MRI.The visual features of every subject were noted. Next, we analyzed the fundamental information, associated medical history, pregnancy outcomes, and different US and MRI signals between the two groups. To determine the potential contributing factors of PAS complicated with bladder involvement, a univariate analysis was performed. A multivariable logistic regression analysis was performed to identify US and MRI findings predictive of bladder involvement in placenta accreta spectrum.
resultsMultiple logistic regression analysis found that the bridging vessels (OR, 31.76,95% CI, 1.64-614.31,p = 0.022) and the tramline sign "fully" obliterated on Crystal Vue feature (OR, 68.92;95%CI,6.76-702.35,p < 0.001) were independently associated with an increased likelihood of bladder involvement. These findings when combined allowed for the prediction of bladder involvement with an 88.2% sensitivity, a 94.4% specificity, and an AUC of 0.933 (95% CI,0.829-0.983, p = 0.001). The results of the MRI logistic regression analysis were as follows: the three independent risk factors for bladder involvement were: Placental bulge (OR,57.99,95%CI,3.89-835.80,p = 0.003),Bladder wall interruption (OR,11.93, 95%CI, 1.60-88.85, p = 0.016), and Bladder vessel sign (OR, 9.75,95%CI, 1.43-66.21, p = 0.020).The joint diagnosis showed a sensitivity of 94.1% and specificity of 83.3%.The area under the curve was 0.942(95%CI,0.841-0.988). Regarding projected bladder involvement, there were no statistically significant differences between MRI and 2D integrated 3D Crystal Vue imaging.
conclusionBoth 2D coupled 3D Crystal Vue imaging and MRI are highly effective for predicting bladder invasion.Ultrasound is preferred over MRI because it is more convenient and more affordable.Among them, the tramline sign "fully" obliterated on 3D Crystal Vue was a new and reliable US sign for detecting bladder involvement.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.