Evidence map›Paper›PMID 39592528›Full record

Article3D printing in medicine2024

Influence of the orientation of constructed blood vessels during the 3D printing on the measurement of the pseudo-oxygen saturation of an artificial blood substitute using conventional oxygen sensors: a test series.

Svenja Jung, Martin Hoffmann, Dirk Winkler, Erdem Güresir, Fabian Kropla, Sebastian Scholz, Ronny Grunert

Abstract read
In one paragraph

Article in 3D printing in medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Svenja JungDepartment of Neurosurgery, University of Leipzig Medical Center, Liebigstr.20, 04103, Leipzig, Germany. svenja.jung@medizin.uni-leipzig.de.
Martin HoffmannDepartment of Neurosurgery, University of Leipzig Medical Center, Liebigstr.20, 04103, Leipzig, Germany.
Dirk WinklerDepartment of Neurosurgery, University of Leipzig Medical Center, Liebigstr.20, 04103, Leipzig, Germany.
Erdem GüresirDepartment of Neurosurgery, University of Leipzig Medical Center, Liebigstr.20, 04103, Leipzig, Germany.
Fabian KroplaDepartment of Neurosurgery, University of Leipzig Medical Center, Liebigstr.20, 04103, Leipzig, Germany.
Sebastian ScholzFraunhofer-Institute for Machine Tools and Forming Technology, 02763, Zittau, Germany.
Ronny GrunertDepartment of Neurosurgery, University of Leipzig Medical Center, Liebigstr.20, 04103, Leipzig, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe development of phantoms to reduce animal testing or to validate new instruments or operation techniques is of increasing importance. For this reason, a blood circulation phantom was developed to test a newly designed retractor system with an integrated oxygen sensor. This phantom was used to evaluate the impact of the 3D printed blood vessel on the measurement of the oxygen saturation.

methodsA solution of nickel sulfate and copper sulfate was prepared as a substitute for real blood. The absorption spectra of these solutions were recorded and compared with those of blood. Subsequently, the oxygen sensor used was calibrated to the blood substitute. Additionally, blood vessels with a simplified geometry were designed and manufactured using inverted vat polymerization and an elastic material (Formlabs Elastic 50 A). To determine the orientation during the printing process, various vessels were printed. Measurements to assess the effects of disturbance (rotation of the vessels during measurements) on the sensor readouts were prepared.

resultsThe impact of disturbances was verified through the rotation of the 3D printed vessels. It was demonstrated that a direct measurement on the disturbances led to outliers and higher values. An optimal orientation was determined to be a lateral placement (90° or 270°) of the sensor. Regarding the orientation of the vessels within the printing space, an orientation of 45° yielded the best results, as the individual layers had the least impact on the light emitted and received by the oxygen sensor.

conclusionThe achieved results demonstrate the influence of the orientation of the vessel during 3D printing as well as the influence of the position of the vessel during the measurement using a conventional oxygen sensor.

Indexed as

3D print3D printed vesselAdditive manufacturingBlood substituteOxygen sensorPhantomR-valueVascular phantom

Identifiers

PMID39592528
PMCPMC11600587

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.