Evidence map›Paper›PMID 39592488›Full record

ArticleEuropean radiology2025

Dual-energy CT of acute bowel ischemia-influence on diagnostic accuracy and reader confidence.

Moritz Oberparleiter, Jan Vosshenrich, Hanns-Christian Breit, Philippe Kaiser, Paul Hehenkamp, Dorothee Harder, Daniel T Boll, Christoph J Zech, Markus M Obmann

Abstract read
In one paragraph

Article in European radiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. [Imaging diagnostics for diseases of the small bowel].Radiologie (Heidelberg, Germany) · 2026
    Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Moritz OberparleiterDepartment of Radiology and Nuclear Medicine, University Hospital Basel, University of Basel, Basel, Switzerland.
Jan VosshenrichDepartment of Radiology and Nuclear Medicine, University Hospital Basel, University of Basel, Basel, Switzerland.
Hanns-Christian BreitDepartment of Radiology and Nuclear Medicine, University Hospital Basel, University of Basel, Basel, Switzerland.
Philippe KaiserDepartment of Radiology and Nuclear Medicine, University Hospital Basel, University of Basel, Basel, Switzerland.
Paul HehenkampDepartment of Radiology and Nuclear Medicine, University Hospital Basel, University of Basel, Basel, Switzerland.
Dorothee HarderDepartment of Radiology and Nuclear Medicine, University Hospital Basel, University of Basel, Basel, Switzerland.
Daniel T BollDepartment of Radiology and Nuclear Medicine, University Hospital Basel, University of Basel, Basel, Switzerland.
Christoph J ZechDepartment of Radiology and Nuclear Medicine, University Hospital Basel, University of Basel, Basel, Switzerland.
Markus M ObmannDepartment of Radiology and Nuclear Medicine, University Hospital Basel, University of Basel, Basel, Switzerland. markus.obmann@gmail.com.ORCID http://orcid.org/0000-0001-6586-0034

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThis study evaluates the advantages in diagnostic accuracy, confidence, and reading time of additional dual-energy CT-derived reconstructions for assessing acute bowel ischemia. METHODS AND MATERIALS: This retrospective study includes 25 patients with surgically proven acute bowel ischemia and 25 gender- and age-matched controls who underwent biphasic abdominal dual-energy CT. Two fellowship-trained abdominal radiologists and two residents evaluated all cases with and without additional dual-energy CT-derived iodine maps and virtual non-contrast images. Diagnostic confidence was rated on a 10-point Likert scale. Reading time was recorded. The inter-reader agreement was assessed using Fleiss' kappa. Sensitivity and specificity were compared using McNemar's test, reader confidence, and reading times with the Wilcoxon signed-rank test.

resultsFor conventional images alone, the inter-reader agreement was moderate (κ = 0.58), with a sensitivity of 77% (95% CI: 67.5-84.8%) and specificity of 90% (95% CI: 82.4-95.1%). Adding dual-energy CT images, inter-reader agreement increased to substantial (κ = 0.69), sensitivity increased significantly to 89% (95% CI: 81.2-94.4%, p = 0.02), while specificity increased non-significantly to 93% (95% CI: 86.1-97.1%, p = 0.51). Diagnostic confidence increased significantly from 8 (IQR: 6-8) to 9 (IQR: 8-9) (p < 0.01). Equivalent diagnostic accuracy and confidence increases were observed for fellowship-trained and resident radiologists. A non-significant increase in mean reading time per case from 196 s to 201 s was observed (p = 0.30).

conclusionAdditional dual-energy CT reconstructions increase diagnostic accuracy and confidence without increasing reading time when evaluating suspected acute bowel ischemia. Both experienced and resident readers benefit from dual-energy CT images. KEY POINTS: Question There are too few clinical studies assessing the diagnostic accuracy of dual-energy CT (DECT) to recommend its use for evaluating suspected acute bowel ischemia. Findings Adding DECT-derived iodine maps and virtual-non-contrast images increase reader sensitivity and confidence while maintaining high specificity when evaluating for acute mesenteric ischemia. Clinical relevance Dual-energy CT should be used to investigate suspected acute bowel ischemia. Both diagnostic accuracy and confidence can be increased independent of reader experience without significantly increasing reading time.

Indexed as

IntestinesIschemiaRadiography, Dual-Energy Scanned ProjectionTomography, X-Ray ComputedAcute DiseaseAdultAgedAged, 80 and overFemaleHumansMaleMiddle AgedObserver VariationRadiographic Image Interpretation, Computer-AssistedReproducibility of ResultsRetrospective StudiesIntestinesMesenteric ischemiaTomography (X-ray computed)

Identifiers

PMID39592488
PMCPMC11836098

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.