Evidence map›Paper›PMID 39590946›Full record

ArticleToxics2024

An Assessment of Surface Contamination and Dermal Exposure to 5-Fluorouracil in Healthcare Settings by UPLC-MS/MS Using a New Atmospheric Pressure Ionization Source.

Matteo Creta, Eline Verscheure, Birgit Tans, Herman Devriese, An Devriendt, David Devolder, Robin Lebegge, Katrien Poels, Lode Godderis, Radu-Corneliu Duca and 1 more

Abstract read
In one paragraph

Article in Toxics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Matteo CretaCentre for Environment and Health, Department of Public Health and Primary Care, University of Leuven (KU Leuven), 3000 Leuven, Belgium.
Eline VerscheureCentre for Environment and Health, Department of Public Health and Primary Care, University of Leuven (KU Leuven), 3000 Leuven, Belgium.
Birgit TansHospital Pharmacy UZ Leuven, University Hospital Leuven (UZ Leuven), 3000 Leuven, Belgium.
Herman DevrieseSafety-Health and Environment, University Hospital Leuven (UZ Leuven), 3000 Leuven, Belgium.
An DevriendtIDEWE, External Service for Prevention and Protection at Work, 3001 Heverlee, Belgium.
David DevolderHospital Pharmacy UZ Leuven, University Hospital Leuven (UZ Leuven), 3000 Leuven, Belgium.
Robin LebeggeCentre for Environment and Health, Department of Public Health and Primary Care, University of Leuven (KU Leuven), 3000 Leuven, Belgium.
Katrien PoelsCentre for Environment and Health, Department of Public Health and Primary Care, University of Leuven (KU Leuven), 3000 Leuven, Belgium.ORCID 0000-0003-4397-6831
Lode GodderisCentre for Environment and Health, Department of Public Health and Primary Care, University of Leuven (KU Leuven), 3000 Leuven, Belgium.ORCID 0000-0003-4764-8835
Radu-Corneliu DucaCentre for Environment and Health, Department of Public Health and Primary Care, University of Leuven (KU Leuven), 3000 Leuven, Belgium.ORCID 0000-0002-9350-3816
Jeroen A J VanoirbeekCentre for Environment and Health, Department of Public Health and Primary Care, University of Leuven (KU Leuven), 3000 Leuven, Belgium.ORCID 0000-0001-5508-3518

Funding

KU Leuven 3M170331Research Foundation - Flanders 1SD2322N
6 · The paper itself

Abstract

5-Fluorouracil (5-FU) is a well-known cytostatic drug, which is often used in cancer treatments. Yet, it is also a very dangerous compound for people who are occupationally exposed to it for a long time, such as pharmacy employees, nurses and cleaning staff. We aimed to improve and implement a LC-MS/MS method for 5-FU quantification on surface contamination samples collected with swabs in a pharmacy department and outpatient nursing station of a university hospital. To improve the existing methods to quantify 5-FU, we compared a LC-MS/MS method using the frequently applied electrospray ionization source (ESI) with a UniSpray ionization source (USI). To determine the contamination of 5-FU in a pharmacy department preparing 5-FU infusion bags, which are then given to patients in the outpatient nursing stations, we collected multiple surface swabs of the laminar flow cabinets and frequently touched objects, before the preparation and administration of 5-FU and afterwards. Furthermore, we sampled the protective gloves and the bare hands of employees of the pharmacy department, involved in the preparation of the infusion bags. Using the USI source, we were able to reach the lowest limit of quantification (LOQ). With this technique, we were able to detect 5-FU contamination on the laminar flow cabinets and frequently used objects in the pharmacy department and the outpatient nursing station in the very low ng/cm

Indexed as

5-fluorouracilantineoplastic drugoccupational exposure

Identifiers

PMID39590946
PMCPMC11598772

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.