Evidence map›Paper›PMID 39590548›Full record

ArticleJournal of functional biomaterials2024

Finite Element Combined Design and Material Optimization Addressing the Wear in Removable Implant Prosthodontics.

Pejman Shayanfard, Xingchen Tan, Matthias Karl, Frank Wendler

Abstract read
In one paragraph

Article in Journal of functional biomaterials, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Pejman ShayanfardDepartment of Materials Science, Institute of Materials Simulation, Friedrich-Alexander University Erlangen-Nürnberg, 90762 Fürth, Germany.
Xingchen TanDepartment of Materials Science, Institute of Materials Simulation, Friedrich-Alexander University Erlangen-Nürnberg, 90762 Fürth, Germany.
Matthias KarlDepartment of Prosthodontics, Saarland University, 66421 Homburg, Germany.ORCID 0000-0002-8748-1024
Frank WendlerDepartment of Materials Science, Institute of Materials Simulation, Friedrich-Alexander University Erlangen-Nürnberg, 90762 Fürth, Germany.ORCID 0000-0003-0622-6003

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Wear at the male-female interface of retentive elements in implant-supported removable prostheses is the most frequent complication in such applications. The lack of an ideal/optimal insertion path, as well as the fabrication inaccuracies, are the primary contributors to this issue. A male attachment with a common ball anchor enhanced by lateral flexibility was investigated as a solution, compared to the widely used rigid ball anchor design. A parametric finite element analysis was performed to compare the wear-inducing maximum strain at the female polymer counterpart by various attachment designs made from titanium and Nitinol. The evolution of mechanical strains causing wear in the female part, as well as the contribution of stresses and martensitic transformation in the implant's flexible shaft, were evaluated under several insertion misfit scenarios. Results indicate that introducing a long flexible shaft in the titanium implant reduced maximum strains in the female attachment part by up to 61% as compared to the solid ball anchor. Further improvement was observed by using the shape memory alloy Nitinol as shaft material, leading to a minor reduction in stress and strain at the contact surface but allowing for a shorter abutment. Finally, the optimized Nitinol implant design with a short, necked flexible shaft promoting martensitic transformation at low plateau stress resulted in an approximate 90% reduction in maximum strains at the inner surface of the female part during manual insertion, which indicates a significantly reduced wear phenomenon at the contact.

Indexed as

design optimizationfinite element methodimplant-supported removable prosthesismaterial optimizationshape memory alloytitaniumwear in female attachment part

Identifiers

PMID39590548
PMCPMC11595149

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.