Evidence map›Paper›PMID 39590285›Full record

ArticleBiomimetics (Basel, Switzerland)2024

Application of Real-Time Palm Imaging with Nelder-Mead Particle Swarm Optimization/Regression Algorithms for Non-Contact Blood Pressure Detection.

Te-Jen Su, Ya-Chung Hung, Wei-Hong Lin, Wen-Rong Yang, Qian-Yi Zhuang, Yan-Xiang Fei, Shih-Ming Wang

Abstract read
In one paragraph

Article in Biomimetics (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Te-Jen SuDepartment of Electronic Engineering, National Kaohsiung University of Sciences and Technology, Kaohsiung 807618, Taiwan.ORCID 0000-0001-7241-0576
Ya-Chung HungDepartment of Electronic Engineering, National Kaohsiung University of Sciences and Technology, Kaohsiung 807618, Taiwan.
Wei-Hong LinDepartment of Electronic Engineering, National Kaohsiung University of Sciences and Technology, Kaohsiung 807618, Taiwan.
Wen-Rong YangDepartment of Electronic Engineering, National Kaohsiung University of Sciences and Technology, Kaohsiung 807618, Taiwan.ORCID 0009-0007-2844-6177
Qian-Yi ZhuangDepartment of Electronic Engineering, National Kaohsiung University of Sciences and Technology, Kaohsiung 807618, Taiwan.ORCID 0009-0006-6411-7293
Yan-Xiang FeiDepartment of Electronic Engineering, National Kaohsiung University of Sciences and Technology, Kaohsiung 807618, Taiwan.
Shih-Ming WangDepartment of Computer Science and Information Engineering, Cheng Shiu University, Kaohsiung 833301, Taiwan.ORCID 0000-0002-8666-7687

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In response to the rising prevalence of hypertension due to lifestyle changes, this study introduces a novel approach for non-contact blood pressure (BP) monitoring. Recognizing the "silent killer" nature of hypertension, this research focuses on developing accessible, non-invasive BP measurement methods. This study compares two distinct non-contact BP measurement approaches: one combining the Nelder-Mead simplex method with particle swarm optimization (NM-PSO) and the other using machine learning regression analysis. In the NM-PSO method, a standard webcam captures continuous images of the palm, extracting physiological data through light wave reflection and employing independent component analysis (ICA) to remove noise artifacts. The NM-PSO achieves a verified root mean square error (RMSE) of 2.71 mmHg for systolic blood pressure (SBP) and 3.42 mmHg for diastolic blood pressure (DBP). Alternatively, the regression method derives BP values through machine learning-based regression formulas, resulting in an RMSE of 2.88 mmHg for SBP and 2.60 mmHg for DBP. Both methods enable fast, accurate, and convenient BP measurement within 10 s, suitable for home use. This study demonstrates a cost-effective solution for non-contact BP monitoring and highlights each method's advantages. The NM-PSO approach emphasizes optimization in noise handling, while the regression method leverages formulaic efficiency in BP estimation. These results offer a biomimetic approach that could replace traditional contact-based BP measurement devices, contributing to enhanced accessibility in hypertension management.

Indexed as

blood pressureindependent component analysismachine learningNelder–Mead simplex methodnon-contact monitoringparticle swarm optimization algorithmregression analysis

Identifiers

PMID39590285
PMCPMC11591982

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.