Evidence map›Paper›PMID 39589975›Full record

ArticleBiosensors2024

A Metal-Organic Framework-Based Colorimetric Sensor Array for Transcutaneous CO

Syed Saad Ahmed, Jingjing Yu, Wei Ding, Sabyasachi Ghosh, David Brumels, Songxin Tan, Laxmi Raj Jaishi, Amirhossein Amjad, Xiaojun Xian

Abstract read
In one paragraph

Article in Biosensors, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Syed Saad AhmedMcComish Department of Electrical Engineering and Computer Science, Jerome J. Lohr College of Engineering, South Dakota State University, Brookings, SD 57007, USA.
Jingjing YuMcComish Department of Electrical Engineering and Computer Science, Jerome J. Lohr College of Engineering, South Dakota State University, Brookings, SD 57007, USA.ORCID 0000-0001-8985-8502
Wei DingMcComish Department of Electrical Engineering and Computer Science, Jerome J. Lohr College of Engineering, South Dakota State University, Brookings, SD 57007, USA.
Sabyasachi GhoshMcComish Department of Electrical Engineering and Computer Science, Jerome J. Lohr College of Engineering, South Dakota State University, Brookings, SD 57007, USA.
David BrumelsMcComish Department of Electrical Engineering and Computer Science, Jerome J. Lohr College of Engineering, South Dakota State University, Brookings, SD 57007, USA.
Songxin TanMcComish Department of Electrical Engineering and Computer Science, Jerome J. Lohr College of Engineering, South Dakota State University, Brookings, SD 57007, USA.ORCID 0000-0002-1367-6697
Laxmi Raj JaishiMcComish Department of Electrical Engineering and Computer Science, Jerome J. Lohr College of Engineering, South Dakota State University, Brookings, SD 57007, USA.
Amirhossein AmjadMcComish Department of Electrical Engineering and Computer Science, Jerome J. Lohr College of Engineering, South Dakota State University, Brookings, SD 57007, USA.
Xiaojun XianMcComish Department of Electrical Engineering and Computer Science, Jerome J. Lohr College of Engineering, South Dakota State University, Brookings, SD 57007, USA.ORCID 0000-0001-6561-5266

Funding

South Dakota Board of Regents FY23 Competitive Research Grant (CRG)South Dakota State University RSCA F24 fund
6 · The paper itself

Abstract

Transcutaneous carbon dioxide (TcPCO2) monitoring provides a non-invasive alternative to measuring arterial carbon dioxide (PaCO2), making it valuable for various applications, such as sleep diagnostics and neonatal care. However, traditional transcutaneous monitors are bulky, expensive, and pose risks such as skin burns. To address these limitations, we have introduced a compact, cost-effective CMOS imager-based sensor for TcPCO2 detection by utilizing colorimetric reactions with metal-organic framework (MOF)-based nano-hybrid materials. The sensor, with a colorimetric sensing array fabricated on an ultrathin PDMS membrane and then adhered to the CMOS imager surface, can record real-time sensing data through image processing without the need for additional optical components, which significantly reduces the sensor's size. Our system shows impressive sensitivity and selectivity, with a low detection limit of 26 ppm, a broad detection range of 0-2% CO

Indexed as

Carbon DioxideColorimetryMetal-Organic FrameworksBiosensing TechniquesBlood Gas Monitoring, TranscutaneousHumansMonitoring, PhysiologicCarbon DioxideMetal-Organic Frameworkscarbon dioxideCMOS Imagercolorimetric sensorMOFstranscutaneous gas

Identifiers

PMID39589975
PMCPMC11591676

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.