ArticleOrthopaedic journal of sports medicine2024
All-Suture Anchor Onlay Fixation for Medial Patellofemoral Ligament Reconstruction: A Biomechanical Comparison of Fixation Constructs.
Article in Orthopaedic journal of sports medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 1 synthesis or guideline pooled it.
- The incidence and epidemiology of patellar fractures following medial patellofemoral ligament reconstruction: a systematic review and meta-analysis.Archives of orthopaedic and trauma surgery · 2026Pooled it
- Lateral Extra-articular Tenodesis Using Knotless All-Suture Anchor Fixation With Suture Tape: A Modified Technique for Augmenting Anterior Cruciate Ligament Reconstruction.Arthroscopy techniques · 2026Article
- Biomechanical Comparison of All-Suture Anchors Versus Interference Screws for Femoral Fixation in Pediatric MPFL Reconstruction.Orthopaedic journal of sports medicine · 2026Article
- Onlay Fixation With an All-Suture Anchor Provides Sufficient Biomechanical Stability for Lateral Extra-articular Tenodesis.Orthopaedic journal of sports medicine · 2025Article
- A Landscape of Recent Literature on the Predictors of Success and Failure in Medial Patellofemoral Ligament Reconstruction.Orthopedic reviews · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: The use of all-suture anchors (ASAs) for onlay patellar and femoral fixation of medial patellofemoral ligament (MPFL) grafts may provide clinical benefit, particularly in the small or pediatric knee; however, biomechanical data supporting the use of ASAs are lacking. Purpose/Hypothesis: The purpose of this study was to compare ASAs to larger interference implants for MPFL reconstruction in a time-zero biomechanical model. It was hypothesized that ASAs would have comparable cyclic elongation to interference fixation and would exceed published biomechanical values for the native human MPFL. Study Design: Controlled laboratory study. Methods: Eighteen fresh-frozen porcine patellas and femurs were divided into equal groups (n = 9 per group) for MPFL reconstructions. Patellar fixation utilized two 3.9-mm interference suture anchors (ISAs) or two 2.6-mm ASAs, while femoral fixation utilized one 6×20-mm interference screw (IS) or one 2.6-mm ASA. Human gracilis tendon grafts were used. Specimens were dynamically loaded for 100 cycles each in sequential 5- to 30-N (phase 1) and 5- to 50-N (phase 2) blocks at 1 Hz followed by load-to-failure testing at 305 mm/min. Results: No differences were found in cyclic elongation after phase 1 and phase 2 loading between ASA and interference implants on either the femoral or patellar side. On the femur, IS had significantly greater ultimate stiffness (54.2 vs 46.1 N/mm; Conclusion: ASA onlay fixation had comparable cyclic elongation to that of interference fixation for femoral and patellar MPFL reconstruction. Although differences in ultimate stiffness and ultimate load were noted between implants, all of the values exceeded published values for the human MPFL. Clinical Relevance: This biomechanical study presents ASA cortical onlay fixation as a viable option for MPFL reconstruction. ASAs require less bone removal, potentially reducing the risk of patellar fracture and minimizing fixation complexity in the setting of open femoral growth plates. Future clinical studies will provide insight into successful tendon-to-bone healing, failure rates, and near- and long-term patient-reported outcomes.