Diaphragmatic Dynamics Assessed by Bedside Ultrasound Predict Extubation in the Intensive Care Unit: A Prospective Observational Study.

Tianjie Zhang, Yan Liu, Dongwei Xu, Rui Dong, Ye Song

Abstract read
In one paragraph

Article in International journal of general medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Observational
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Tianjie ZhangDepartment of Ultrasonography, Shanghai University of Medicine and Health Sciences Affiliated Zhoupu Hospital, Shanghai, 201318,People's Republic of China.
Yan LiuDepartment of Ultrasonography, Shanghai University of Medicine and Health Sciences Affiliated Zhoupu Hospital, Shanghai, 201318,People's Republic of China.
Dongwei XuDepartment of Critical Care Medicine, Shanghai University of Medicine and Health Sciences Affiliated Zhoupu Hospital, Shanghai, People's Republic of China.
Rui DongDepartment of Ultrasonography, Shanghai University of Medicine and Health Sciences Affiliated Zhoupu Hospital, Shanghai, 201318,People's Republic of China.
Ye SongDepartment of Ultrasonography, Shanghai University of Medicine and Health Sciences Affiliated Zhoupu Hospital, Shanghai, 201318,People's Republic of China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: This study aims to evaluate the predictive value of bedside ultrasound evaluation of diaphragmatic dynamics in determining successful extubation outcomes for patients eligible for weaning. Methods: This prospective observational study was conducted on patients who were mechanically ventilated and ready for weaning during the spontaneous breathing trial (SBT). The diaphragm contraction and motion-related parameters of patients such as end inspiratory diaphragm thickness (DT-insp), end respiratory diaphragm thickness (DT-exp), diaphragm thickening fraction (DTF), diaphragmatic thickening fraction rapid shallow breathing index (DTF-RSBI), diaphragmatic excursion (DE), diaphragmatic excursion rapid shallow breathing index (DE-RSBI) were recorded and the association with failure in ventilatory extubation was analyzed. A receiver operating characteristic (ROC) curve was conducted to analyze the prediction of successful weaning. Results: Out of 95 patients, 14 (14.74%) died, and 68 (71.58%) were successfully extubated. There were significant differences between the two groups in all parameters except DT-exp. The results indicated that duration of mechanical ventilation (OR = 0.850, 95% CI: 0.770-0.938, P = 0.001), DTF (OR = 1.214, 95% CI: 1.108-1.330, P = 0.000), DTF-RSBI (OR = 0.917, 95% CI: 0.880-0.954, P = 0.000), DE (OR = 127.02, 95% CI: 15.004-1075.291, P = 0.000), DE-RSBI (OR = 0.752, 95% CI: 0.657-0.861, P = 0.000) had predictive value for weaning. DTF and DE had a high sensitivity of 91.18%, 100%, respectively. Whereas, duration of mechanical ventilation, DTF-RSBI, DE-RSBI showed a high specificity of 81.48,85.19%, 81.48%. Considering all the above factors, the sensitivity was 88.24% and the specificity was 88.89%. Conclusion: Bedside ultrasound assessment of diaphragmatic parameters enables the detection of diaphragmatic dysfunction, thus proving valuable in predicting extubation success and facilitating a favorable weaning outcome.

Indexed as

bedside ultrasounddiaphragmatic dynamicsextubationintensive care unit

Identifiers

PMID39582920
PMCPMC11584334

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.