ArticleApplied magnetic resonance2024
Challenges of Continuous Wave EPR of Broad Signals-The Ferritin Case.
Article in Applied magnetic resonance, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Temperature Dependence of Paramagnetic Species in the Human Brain Tissue: An X-Band EPR Study.Magnetic resonance in medicine · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The study of continuous wave (cw) electron paramagnetic resonance (EPR) spectra still poses a challenge for very broad signals, especially when the spectrum extends over a large part of the accessible field range. The difficulties derive from instrumental challenges, because of insufficient modulation depth and the need to apply measurement conditions that enhance cavity background. The biggest problem, however, is how to define a baseline such that spectral distortions are minimized. Conventional methods rely on a suitable choice of points outside the range of the signal of interest to perform a polynomial interpolation. These methods are effective in most cases where the signal of interest comprises only a narrow range of magnetic field (narrow features). In this study, a novel method of baseline correction for broad signals is proposed and compared to conventional methods. It takes into account that there are only few anchor points for the baseline. The method is applied to the signal of the iron-storage protein ferritin. The ferritin signal is a broad band that extends from zero to 0.8 T. An approach is developed by which this broad signal is analyzed reliably. The method is also extended to the case where the broad signal is superimposed on narrow signals and enables to extract the parameters of both types of signals in a fitting pipeline. Supplementary Information: The online version contains supplementary material available at 10.1007/s00723-024-01719-y.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.