Evidence map›Paper›PMID 39582220›Full record

ArticleThe American journal of sports medicine2024

Accuracy of Combined High Tibial Slope Correction Osteotomy Using 3-Dimensional-Planned Patient-Specific Instrumentation.

Christoph Zindel, Sandro Hodel, Lukas Jud, Stefan M Zimmermann, Lazaros Vlachopoulos, Sandro F Fucentese

Abstract read
In one paragraph

Article in The American journal of sports medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Accuracy of medial opening wedge high tibial osteotomy using patient-specific instrumentation: a randomised cadaveric study.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2025
    Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Christoph ZindelDepartment of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.ORCID 0000-0002-6253-9824
Sandro HodelDepartment of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.
Lukas JudDepartment of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.ORCID 0000-0001-8128-3927
Stefan M ZimmermannDepartment of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.
Lazaros VlachopoulosDepartment of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.
Sandro F FucenteseDepartment of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIf an increased posterior tibial slope (PTS) and concomitant unicompartmental osteoarthritis are present, a simultaneous sagittal (slope) and coronal correcting high tibial osteotomy has been recommended. However, no study has investigated the accuracy of such combined high tibial slope correction osteotomies. PURPOSE: (1) To report the accuracy of navigated high tibial slope correction osteotomies using patient-specific instruments (PSI) and (2) to analyze the influence of an open wedge osteotomy (OWO) versus a closed wedge osteotomy (CWO) and the hinge axis angle (HAA) on the accuracy of the PTS correction. STUDY

designCohort study; Level of evidence, 3.

methodsAll PSI PTS-reducing osteotomies performed at 1 institution between 2019 and 2022 were reviewed. Three-dimensional (3D) accuracy was defined as the mean absolute 3D angular difference between the planned and achieved surgical correction (in degrees) in 3D models of computed tomography data. The influence of OWO versus CWO and the HAA on the reported accuracy was analyzed and a cutoff defined using receiver operating characteristic curve analysis.

resultsEighteen patients who underwent a slope-reducing CWO (n = 9) or OWO (n = 9) were included. The 3D accuracy for PTS was 2.3°± 1.1° (mean ± SD), with CWO being more accurate than OWO (1.4°± 0.9° vs 3.1°± 0.6°;

conclusionSlope-reducing osteotomy can accurately be achieved using PSI. CWO demonstrated an increased accuracy when compared with OWO, which strongly depended on the HAA. With an aim of combined PTS and coronal correction, CWO should be considered the primary choice for accurate slope reduction with a coronal/sagittal correction cutoff of 0.8:1 (HAA, 38.9°).

Indexed as

Osteoarthritis, KneeOsteotomyTibiaAdultFemaleHumansImaging, Three-DimensionalMaleMiddle AgedRetrospective StudiesTomography, X-Ray Computed3D preoperative planning.high tibial osteotomypatient-specific instrumentsposterior slope

Identifiers

PMID39582220
PMCPMC11608524

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.