Prospective Clinical Study on the Accuracy of Static Computer-Assisted Implant Surgery in Patients With Distal Free-End Implants. Conventional Versus CAD-CAM Surgical Guides.
Trial report in Clinical oral implants research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06404385 (Prospective Clinical Study on the Accuracy of Static Computer-assisted Implant Surgery in Patients Rehabilitated With Distal Free-end Implants. Conventional Versus CAD-CAM Surgical Guides), which is not on this map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Prospective Clinical Study on the Accuracy of Static Computer-assisted Implant Surgery in Patients Rehabilitated With Distal Free-end Implants. Conventional Versus CAD-CAM Surgical Guides
Who cites it
2 citing papers in PubMed.
- Digital Dentistry in Clinical Practice: A Scoping Review of Current Capabilities and Future Directions.International dental journal · 2026Article
- Accuracy of Three-Dimensional Computer-Aided Implant Surgical Guides: A Prospective In Vivo Study of the Impact of Template Design.Dentistry journal · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesTo compare the accuracy of CAD-CAM and conventional guides in the static computer-assisted implant surgery (sCAIS) placement of distal free-end implants. MATERIAL AND
methodsA prospective, controlled, and blinded quasi-experimental study was done involving 27 patients (76 implants) distributed into two groups according to the surgical guide manufacturing approach used: conventional (control group [CG]) or CAD-CAM (test group [TG]). The implants were planned in the software and the surgical guides were manufactured. Fully guided implant placement was carried out and the deviations were measured along with secondary variables as potential confounding factors. Descriptive analyses were performed on mean, standard deviation (SD), and interquartile range (IQR). In the comparative/inferential analysis hypothesis, contrasts were made of the quantitative and qualitative variables and multiple linear models were generated to adjust for the different confounding variables recorded.
resultsCoronal horizontal deviation (CHD) was significantly greater in CG (1.52 mm) versus TG (1.04 mm) (p = 0.004). Apical horizontal deviation (AHD) in turn was 1.67 versus 1.46 mm, respectively; angular deviation was 2.87 versus 3.64; and vertical deviation was -0.1 versus -0.05 mm, with no significant differences between the groups (p > 0.05). A greater sleeve height, positioning in premolars versus molars, and the use of shorter implants, were associated with greater accuracy in relation to CHD and/or AHD (p < 0.05). The implant success rate at 1 year was 92.1%, 90.7% in TG, and 100% in CG, being statistically significant (p = 0.026) at the implant level, but not significant at the patient level.
conclusionsThe CAD-CAM surgical guides proved to be more accurate than the conventional guides in the sCAIS placement of distal free-end implants, with statistically significant differences being observed in terms of CHD. All implant failures occurred in TG (6 implants/3 patients).
trial registrationClinicalTrials.gov identifier: NCT06404385.