Evidence map›Paper›PMID 39578942›Full record

Trial reportClinical oral implants research2025

Prospective Clinical Study on the Accuracy of Static Computer-Assisted Implant Surgery in Patients With Distal Free-End Implants. Conventional Versus CAD-CAM Surgical Guides.

García-Mira Berta, Canullo Luigi, Peñarrocha-Diago Miguel, Balaguer-Martí José Carlos

Registry-linked trialAbstract readClinical TrialComparative Study
In one paragraph

Trial report in Clinical oral implants research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06404385 (Prospective Clinical Study on the Accuracy of Static Computer-assisted Implant Surgery in Patients Rehabilitated With Distal Free-end Implants. Conventional Versus CAD-CAM Surgical Guides), which is not on this map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT06404385 nacompletednot on this map

Prospective Clinical Study on the Accuracy of Static Computer-assisted Implant Surgery in Patients Rehabilitated With Distal Free-end Implants. Conventional Versus CAD-CAM Surgical Guides

TypeinterventionalSponsorUniversity of ValenciaRan2012 to 2019Enrolled27ConditionsDental Implant, Computer-assistedArmsStatic computer-assisted guided surgery with analogic guide, Static computer-assisted guided surgery with CAD-CAM surgical guide
3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

García-Mira BertaUniversity of Valencia, Valencia, Spain.ORCID 0000-0001-5789-973X
Canullo LuigiDepartment of Surgical Sciences, University of Genova, Genova, Italy.
Peñarrocha-Diago MiguelUniversity of Valencia, Valencia, Spain.
Balaguer-Martí José CarlosUniversity of Valencia, Valencia, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo compare the accuracy of CAD-CAM and conventional guides in the static computer-assisted implant surgery (sCAIS) placement of distal free-end implants. MATERIAL AND

methodsA prospective, controlled, and blinded quasi-experimental study was done involving 27 patients (76 implants) distributed into two groups according to the surgical guide manufacturing approach used: conventional (control group [CG]) or CAD-CAM (test group [TG]). The implants were planned in the software and the surgical guides were manufactured. Fully guided implant placement was carried out and the deviations were measured along with secondary variables as potential confounding factors. Descriptive analyses were performed on mean, standard deviation (SD), and interquartile range (IQR). In the comparative/inferential analysis hypothesis, contrasts were made of the quantitative and qualitative variables and multiple linear models were generated to adjust for the different confounding variables recorded.

resultsCoronal horizontal deviation (CHD) was significantly greater in CG (1.52 mm) versus TG (1.04 mm) (p = 0.004). Apical horizontal deviation (AHD) in turn was 1.67 versus 1.46 mm, respectively; angular deviation was 2.87 versus 3.64; and vertical deviation was -0.1 versus -0.05 mm, with no significant differences between the groups (p > 0.05). A greater sleeve height, positioning in premolars versus molars, and the use of shorter implants, were associated with greater accuracy in relation to CHD and/or AHD (p < 0.05). The implant success rate at 1 year was 92.1%, 90.7% in TG, and 100% in CG, being statistically significant (p = 0.026) at the implant level, but not significant at the patient level.

conclusionsThe CAD-CAM surgical guides proved to be more accurate than the conventional guides in the sCAIS placement of distal free-end implants, with statistically significant differences being observed in terms of CHD. All implant failures occurred in TG (6 implants/3 patients).

trial registrationClinicalTrials.gov identifier: NCT06404385.

Indexed as

Computer-Aided DesignDental Implantation, EndosseousDental ImplantsSurgery, Computer-AssistedAdultAgedFemaleHumansMaleMiddle AgedProspective StudiesDental Implantsaccuracyanalogiccomputer‐aided designcomputer‐assisted surgerydental implants

Identifiers

PMID39578942
PMCPMC11891034

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.