ArticleThe international journal of medical robotics + computer assisted surgery : MRCAS2024
Validation of an Augmented Reality Based Functional Method to Determine and Render the Hip Rotation Centre During Total Hip Arthroplasty.
Article in The international journal of medical robotics + computer assisted surgery : MRCAS, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundWe present a method to determine and visualise the functional centre of rotation (FCOR) of the hip during total hip arthroplasty using an augmented reality head mounted display (AR-HMD).
methodsWe developed software allowing a HoloLens to provide inside-out infrared tracking of markers affixed to cadaver femurs and 3D printed acetabuli. Two observers rotated 20 cadaver femurs twice in a matching cup, producing 80 measurements. The FCOR of the acetabulum and femoral head was determined based on the point cloud generated from the displacement of the femoral trackers to the acetabular tracker.
resultsCompared to the ground truth, the FCOR resulted in an absolute error of 2.9 ± 1.4 mm for the acetabulum and 2.9 ± 1.2 mm for the femur, with 95th percentiles below 5.6 and 4.7 mm.
conclusionThe proposed AR-HMD system offers an accurate and reproducible way to determine the femoral and acetabular FCOR in an experimental setting.