Evidence map›Paper›PMID 39576393›Full record

ArticleActa neurochirurgica2024

Radiation exposure and safety in low-dose CT-guided glycerol rhizotomy for trigeminal Neuralgia outside the operating room.

Jiri Dostal, Jan Baxa, Jana Stepankova, Miroslav Seidl, Jan Mracek, Pavel Lavicka, Tomas Malkus, Vladimir Priban

Erratum issuedAbstract read
In one paragraph

Article in Acta neurochirurgica, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

8 authors.

Jiri DostalDepartment of Neurosurgery, Faculty of Medicine in Pilsen, Charles University, University Hospital, Pilsen, Czech Republic. dostalj@fnplzen.cz.ORCID 0000-0002-1483-8117
Jan BaxaDepartment of Imaging Methods, Faculty of Medicine in Pilsen, Charles University, University Hospital, Pilsen, Czech Republic.ORCID 0000-0002-4896-1658
Jana StepankovaDepartment of Radiological Physics, Faculty of Medicine in Pilsen, Charles University, University Hospital, Pilsen, Czech Republic.ORCID 0009-0007-9534-9326
Miroslav SeidlDepartment of Neurosurgery, Faculty of Medicine, University of Ostrava, University Hospital, Ostrava, Czech Republic.ORCID 0009-0004-3862-1491
Jan MracekDepartment of Neurosurgery, Faculty of Medicine in Pilsen, Charles University, University Hospital, Pilsen, Czech Republic.ORCID 0000-0002-4629-4732
Pavel LavickaDepartment of Neurosurgery, Faculty of Medicine in Pilsen, Charles University, University Hospital, Pilsen, Czech Republic.ORCID 0009-0009-5016-7654
Tomas MalkusDepartment of Imaging Methods, Faculty of Medicine in Pilsen, Charles University, University Hospital, Pilsen, Czech Republic.ORCID 0000-0001-9268-5366
Vladimir PribanDepartment of Neurosurgery, Faculty of Medicine in Pilsen, Charles University, University Hospital, Pilsen, Czech Republic.ORCID 0000-0001-6051-9910

Funding

Ministerstvo Zdravotnictví Ceské Republiky FNPl, 00669806
6 · The paper itself

Abstract

backgroundPercutaneous rhizotomy of the Gasserian ganglion is a well-established intervention for patients suffering from refractory trigeminal pain, not amenable to pharmacological management or microvascular decompression. Traditionally conducted under fluoroscopic guidance using Hartel's technique, this study investigates a modified approach employing low-dose CT guidance to achieve maximal procedural precision and safety with the emphasis on minimizing radiation exposure.

methodsA retrospective analysis of patients undergoing percutaneous rhizotomy of the Gasserian ganglion at our institution was undertaken. Procedures were divided into fluoroscopy and CT-guided foramen ovale (FO) cannulation cohorts. Radiation doses were assessed, excluding cases with incomplete data. The study included 32 procedures in the fluoroscopy group and 30 in the CT group.

resultsIn the CT-guided group, the median effective dose was 0.21 mSv. The median number of CT scans per procedure was 4.5, and the median procedure time was 15 min. Successful FO cannulation was achieved in all 30 procedures (100%). In the fluoroscopy group, the median effective dose was 0.022 mSv, and the median procedure time was 15 min. Cannulation of FO was successful in 31 of 32 procedures (96.9%). The only complications in the CT-guided group were three minor cheek hematomas. Immediate pain relief in the CT-guided group was reported in 25 of 30 procedures (83.3%), 22 of 30 (73.3%) provided relief at one month, and 10 of 18 (55.6%) procedures resulting in pain relief at one month continued to provide relief after two years.

conclusionLow-dose CT-guided percutaneous rhizotomy conducted in the radiology suite carries negligible radiation exposure for patients and eliminates it for personnel. This method is fast, simple, precise, and carries a very low risk of complications.

Indexed as

Radiation ExposureRhizotomyTomography, X-Ray ComputedTrigeminal NeuralgiaAdultAgedFemaleFluoroscopyHumansMaleMiddle AgedRadiation DosageRetrospective StudiesTreatment OutcomeTrigeminal Ganglion

Identifiers

PMID39576393
PMCPMC11584485

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.