Evidence map›Paper›PMID 39575326›Full record

ArticleWearable technologies2024

A muscle synergies-based controller to drive a powered upper-limb exoskeleton in reaching tasks.

Michele Francesco Penna, Luca Giordano, Stefano Tortora, Davide Astarita, Lorenzo Amato, Filippo Dell'Agnello, Emanuele Menegatti, Emanuele Gruppioni, Nicola Vitiello, Simona Crea and 1 more

Abstract read
In one paragraph

Article in Wearable technologies, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Michele Francesco PennaThe BioRobotics Institute, Scuola Superiore Sant'Anna, Pontedera, Italy.ORCID https://orcid.org/0000-0002-2296-3743
Luca GiordanoThe BioRobotics Institute, Scuola Superiore Sant'Anna, Pontedera, Italy.
Stefano TortoraDepartment of Information Engineering, University of Padova, Padova, Italy.
Davide AstaritaThe BioRobotics Institute, Scuola Superiore Sant'Anna, Pontedera, Italy.
Lorenzo AmatoThe BioRobotics Institute, Scuola Superiore Sant'Anna, Pontedera, Italy.
Filippo Dell'AgnelloThe BioRobotics Institute, Scuola Superiore Sant'Anna, Pontedera, Italy.
Emanuele MenegattiDepartment of Information Engineering, University of Padova, Padova, Italy.
Emanuele GruppioniCentro Protesi Inail di Vigorso di Budrio, Bologna, Italy.
Nicola VitielloThe BioRobotics Institute, Scuola Superiore Sant'Anna, Pontedera, Italy.
Simona CreaThe BioRobotics Institute, Scuola Superiore Sant'Anna, Pontedera, Italy.ORCID https://orcid.org/0000-0001-9833-4401
Emilio TrigiliThe BioRobotics Institute, Scuola Superiore Sant'Anna, Pontedera, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This work introduces a real-time intention decoding algorithm grounded in muscle synergies (Syn-ID). The algorithm detects the electromyographic (EMG) onset and infers the direction of the movement during reaching tasks to control a powered shoulder-elbow exoskeleton. Features related to muscle synergies are used in a Gaussian Mixture Model and probability accumulation-based logic to infer the user's movement direction. The performance of the algorithm was verified by a feasibility study including eight healthy participants. The experiments comprised a transparent session, during which the exoskeleton did not provide any assistance, and an assistive session in which the Syn-ID strategy was employed. Participants were asked to reach eight targets equally spaced on a circumference of 25 cm radius (adjusted chance level: 18.1%). The results showed an average accuracy of 48.7% after 0.6 s from the EMG onset. Most of the confusion of the estimate was found along directions adjacent to the actual one (type 1 error: 33.4%). Effects of the assistance were observed in a statistically significant reduction in the activation of Posterior Deltoid and Triceps Brachii. The final positions of the movements during the assistive session were on average 1.42 cm far from the expected ones, both when the directions were estimated correctly and when type 1 errors occurred. Therefore, combining accurate estimates with type 1 errors, we computed a modified accuracy of 82.10±6.34%. Results were benchmarked with respect to a purely kinematics-based approach. The Syn-ID showed better performance in the first portion of the movement (0.14 s after EMG onset).

Indexed as

electromyographyExoskeletonsIntention decodingwearable robotics

Identifiers

PMID39575326
PMCPMC11579892

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.