Evidence map›Paper›PMID 39575213›Full record

ArticleJournal of the Society for Cardiovascular Angiography & Interventions2024

A Novel Protocol for Contrast-Free Transcatheter Aortic Valve Replacement Evaluation and Implantation.

David Elison, Barbara A Danek, Bryce V Johnson, Christine J Chung, Shakirat Oyetunji, G Burkhard Mackensen, Gabriel Aldea, James M McCabe

Abstract read
In one paragraph

Article in Journal of the Society for Cardiovascular Angiography & Interventions, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Zero-Contrast TAVR: Inching Toward Safer TAVR in Patients With Kidney Disease.Journal of the Society for Cardiovascular Angiography & Interventions · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

David ElisonDivision of Cardiovascular Medicine, Department of Medicine, University of Washington, Seattle, Washington.
Barbara A DanekDivision of Cardiovascular Medicine, Department of Medicine, University of Washington, Seattle, Washington.
Bryce V JohnsonDivision of Cardiovascular Medicine, Department of Medicine, University of Washington, Seattle, Washington.
Christine J ChungDivision of Cardiovascular Medicine, Department of Medicine, University of Washington, Seattle, Washington.
Shakirat OyetunjiDivision of Cardiothoracic Surgery, Department of Surgery, University of Washington, Seattle, Washington.
G Burkhard MackensenDivision of Cardiothoracic Anesthesiology, Department of Anesthesiology and Pain Medicine, University of Washington, Seattle, Washington.
Gabriel AldeaDivision of Cardiothoracic Surgery, Department of Surgery, University of Washington, Seattle, Washington.
James M McCabeDivision of Cardiovascular Medicine, Department of Medicine, University of Washington, Seattle, Washington.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: We aimed to develop a transcatheter aortic valve replacement (TAVR) sizing algorithm and implantation method to facilitate safe and effective TAVR without contrast use in patients with severe chronic kidney disease (CKD) who do not yet require renal replacement therapy. Patients with CKD are a challenging patient subset to treat using standard TAVR care pathways which most usually require the use of iodinated contrast media both during gated computed tomography (CT) angiography sizing, and valve deployment. Iodinated contrast exposure may worsen kidney function in a dose-dependent fashion, and may result in a need for renal replacement therapy. Therefore, a method to eliminate, or greatly lessen, contrast exposure during TAVR is highly desirable. Methods: One hundred sixty patients who underwent standard CT angiography and TAVR implantation were used to develop (100 patients) and validate (60 patients) an algorithm to predict balloon-expandable valve size using measurements available from noncontrast CT. Model accuracy was measured using Pearson correlation between algorithm-predicted valve size and actual size used based on annular area. As proof of concept, we then report a case series of 35 consecutive patients who underwent TAVR evaluation and implantation with moderate sedation and no contrast between May 2021 and April 2024. Results: The valve sizing algorithm incorporates sinus and sinotubular junction diameters, both available from a reformatted noncontrast, cardiac-gated CT. The algorithm demonstrated a strong correlation with the actual valve size used (development cohort R = 0.81, validation cohort R = 0.76). Thirty-five patients underwent "no-contrast TAVR" with noncontrast CT for valve sizing. Forty-eight percent were urgent inpatient TAVR. Technical procedural success, as defined by the VARC3 criteria, was 100%, with no patient deaths during the index procedure. Three patients had a mild paravalvular leak. No valve embolization or need for a second valve occurred. Four patients required a pacemaker. Conclusions: We present a novel algorithm for TAVR evaluation and implantation without the use of iodinated contrast media in a high-risk patient subset with CKD.

Indexed as

acute kidney injuryaortic stenosischronic kidney diseasecomputed tomographycontrast freetranscatheter aortic valve replacement

Identifiers

PMID39575213
PMCPMC11576374

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.