ArticleCureus2024

Electroencephalogram of Normotensive Individuals During Sitting and Standing Blood Pressure Measurement Positions.

Mayowa J Adeniyi, Ayobami A Adamu, Ayoola Awosika

Abstract read
In one paragraph

Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Mayowa J AdeniyiDepartment of Physiology, Federal University of Health Sciences, Otukpo, NGA.
Ayobami A AdamuDepartment of Anesthesia, Ekiti State University Teaching Hospital, Ado-Ekiti, NGA.
Ayoola AwosikaCollege of Medicine, University of Illinois, Chicago, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background Investigating changes in brain electroencephalogram activity during blood pressure measurement in sitting and standing positions is clinically significant for understanding the neural correlates of postural changes, which may affect cerebral perfusion and autonomic regulation. Shifts in blood pressure can influence visual cortical activity, potentially altering cognitive and sensory processing. This research holds clinical relevance in evaluating disorders like orthostatic hypotension and syncope, where postural changes compromise cerebral blood flow. Furthermore, it can help refine diagnostic protocols and management strategies for neurovascular and autonomic dysfunction. The study also highlighted the possibility of using polygraphs to identify and manage discrepancies in blood pressure measurement caused by posture-induced changes in brain activities for accurate diagnosis. Methodology The electroencephalogram of healthy normotensive female individuals undergoing blood pressure measurements at sitting and standing positions was investigated. Ten healthy young adult females who satisfy the inclusion criteria were selected. Electroencephalographic (EEG) waves were recorded with the aid of Powerlab 26T (ADInstruments Pty Ltd., Bella Vista, Australia). Blood pressure and pulse rate measurements were conducted using a sphygmomanometer and stopwatch. Results During sitting and standing blood pressure positions, diastolic blood pressure and pulse rate were higher when compared to baseline values but the standing blood pressure position showed a higher pulse rate than the sitting blood pressure position. Although alpha wave frequency was higher during both sitting and standing blood pressure measurement positions, the standing blood pressure position caused lower alpha wave frequency when compared with the sitting blood pressure measurement position. While a strong negative correlation was found between alpha wave frequency and pulse rate, beta wave frequency positively correlated with pulse rate during sitting blood pressure measurement position. Furthermore, during standing blood pressure measurement position, the alpha wave did not correlate with pulse rate nor was there a correlation between beta wave frequency and pulse rate. In conclusion, the present study indicated that both sitting and standing blood pressure measurement positions caused a decrease in alpha wave frequency when compared with baseline, but the standing blood pressure measurement position elicited a lower alpha wave frequency when compared with the sitting blood pressure measurement position.

Indexed as

alpha wavesbeta waveeeg (electroencephalogram)powerlabsphygmomanometer

Identifiers

PMID39575011
PMCPMC11581456

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.