Evidence map›Paper›PMID 39572450›Full record

ArticleEuropean journal of applied physiology2025

The impact of skinfold thickness and exercise intensity on the reliability of NIRS in the vastus lateralis.

Lena Stuer, Massimo Teso, Alessandro L Colosio, Maura Loi, Patrick Mucci, Silvia Pogliaghi, Jan Boone, Kevin Caen

Abstract read
PubMed Publisher
In one paragraph

Article in European journal of applied physiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Lena StuerDepartment of Movement and Sport Sciences, Ghent University, Watersportlaan 2, 9000, Ghent, Belgium.
Massimo TesoDepartment of Neurosciences, Biomedicine and Movement Sciences, University of Verona, Verona, Italy.
Alessandro L ColosioDepartment of Movement and Sport Sciences, Ghent University, Watersportlaan 2, 9000, Ghent, Belgium.
Maura LoiDepartment of Neurosciences, Biomedicine and Movement Sciences, University of Verona, Verona, Italy.
Patrick MucciUniv. Lille, Univ. Artois, Univ. Littoral Côte d'Opale, ULR, URePSSS-Unité de Recherche Pluridisciplinaire Sport Santé Société, 7369, 59000, Lille, France.
Silvia PogliaghiDepartment of Neurosciences, Biomedicine and Movement Sciences, University of Verona, Verona, Italy.
Jan BooneDepartment of Movement and Sport Sciences, Ghent University, Watersportlaan 2, 9000, Ghent, Belgium. jan.boone@UGent.be.ORCID http://orcid.org/0000-0002-8485-6169
Kevin CaenDepartment of Movement and Sport Sciences, Ghent University, Watersportlaan 2, 9000, Ghent, Belgium.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe aims of this study were (1) to assess the test-retest reliability of the primary near infrared spectroscopy (NIRS) variables (i.e., StO

methods21 men and 20 women completed twelve constant work rate tests (6 min) at six different exercise intensities with each intensity performed twice. NIRS variables were measured at the vastus lateralis. The coefficient of variance (CV%), the intraclass correlation coefficient (ICC), mean bias and limits of agreement (LoA) were determined for reliability purposes.

resultsThe reliability of baseline values were acceptable to very good (CV% range: 5.83 - 21.96%). The reliability of end-values (CV% range: 0.02 - 25.02%, ICC range: 0.0 - 0.935) and amplitudes (CV% range: 0.46 - 5099%, ICC range: 0.0 - 0.887) were more variable. In general, the mean biases of end-values and amplitudes showed wide limits of agreement. A homogeneous influence of exercise intensity on reliability could not be established but reliability measures appeared to be lower in people with a lower skinfold thickness. Moreover, the NIRS signals decreased with increasing ATT but stabilized upon reaching a cut-off of 8 mm ATT. In addition, ATT did have a significant influence on [HHb] amplitude. In participants with ATT < 8 mm, higher amplitudes were observed with increasing intensity whereas in participants with ATT > 8 mm, there were no differences between the intensities.

conclusionThe study reveals variable results with regards to reliability and there was no consistent influence of exercise intensity on reliability. Participants with a lower skinfold thickness showed stronger reliability. Moreover, NIRS signals decrease when ATT exceeds 8 mm. Careful consideration is necessary when interpreting NIRS signals in such cases.

Indexed as

ExerciseQuadriceps MuscleSkinfold ThicknessAdultFemaleHumansMaleOxygen ConsumptionReproducibility of ResultsSpectroscopy, Near-InfraredYoung AdultNIRSOxidative metabolismReliabilityVastus lateralis

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.