ArticleClinical orthopaedics and related research2025
Robotic Assistance Is Not Associated With Decreased Early Revisions in Cementless TKA: An Analysis of the American Joint Replacement Registry.
Article in Clinical orthopaedics and related research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Robot-assisted total knee arthroplasty and the risk of postoperative infection: a systematic review and meta-analysis.Journal of robotic surgery · 2026Pooled it
- Highlights of the 2025 American Joint Replacement Registry Annual Report.Arthroplasty today · 2026Article
- Asia-Pacific expert consensus on robotic-assisted hip and knee arthroplasty.Arthroplasty (London, England) · 2026Review
- Ninety-day readmission and early complications after coding-defined cementless-category versus cemented-category primary total knee arthroplasty.Arthroplasty (London, England) · 2026Article
- Beyond Precision: Why the Future of Robotic Joint Arthroplasty Demands Continued Research.Arthroplasty today · 2026Article
- Robotic-assisted and AI-augmented arthroplasty: converging technologies in joint replacement.Journal of robotic surgery · 2026Review
- Excellent Short-Term Outcomes After Kinematic Alignment, Medial-Pivot Total Knee Arthroplasty for Isolated Patellofemoral Osteoarthritis.Arthroplasty today · 2026Article
- Similar clinical and survival outcomes between robotic-assisted cemented and cementless total knee arthroplasty.Archives of orthopaedic and trauma surgery · 2025Article
- Femoral resection accuracy and precision in manual caliper-verified kinematic alignment total knee arthroplasty.Journal of experimental orthopaedics · 2025Article
- CORR Insights®: Robotic Assistance Is Not Associated With Decreased Early Revisions in Cementless TKA: An Analysis of the American Joint Replacement Registry.Clinical orthopaedics and related research · 2025Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundPreviously, we conducted a retrospective study of American Joint Replacement Registry (AJRR) data that examined the 2-year odds of revision between robotic-assisted and nonrobotic-assisted TKA, and we found no benefit to robotic assistance. However, proponents of robotic assistance have suggested that robot platforms confer more accurate bone cuts and precise implant sizing that might promote osteointegration of cementless implants by limiting micromotion at the bone-implant interface that could lead to aseptic loosening. Therefore, it seems important specifically to evaluate the odds of revision among patients with cementless implants only within our previous study population. QUESTIONS/PURPOSES: (1) After controlling for potentially confounding variables, such as surgeon, institution, and patient comorbidity profile, was robotic assistance associated with a decreased odds of 2-year revision of cementless TKA for any reason compared with cementless TKAs performed without robotic assistance? (2) After again controlling for potentially confounding variables, was robotic assistance associated with a decreased odds of 2-year revision of cementless TKA for particular revision indications (such as aseptic loosening, infection, instability, or pain) compared with the cementless TKAs performed without robotic assistance?
methodsUsing the AJRR, a retrospective cohort of patients ≥ 65 years of age with osteoarthritis who underwent primary TKA with cementless femur and tibial components from January 2017 through March 2020 was identified. Procedures performed with hybrid fixation (cement only on the tibia but not on the femur, or vice versa) were excluded. The AJRR was selected because it is the largest arthroplasty registry in the world by annual procedure volume, and it contains a data linkage with inpatient and outpatient Medicare claims data to ensure near-complete 2-year follow-up. A total of 9220 patients were identified, and robotic assistance was used in 45% (4130) of procedures. Patient age did not differ between groups (72 ± 5 years versus 72 ± 5 years; p = 0.29). However, the robotic-assisted cohort had a slightly higher proportion of female patients (56% [2332 of 4130] versus 53% [2693 of 5090]; p = 0.002) and higher Charlson comorbidity index (CCI) (2.9 ± 0.9 versus 2.8 ± 0.9; p = 0.003). Therefore, a mixed-effects model was used to analyze the ORs for all-cause linked revision with robotic assistance and was adjusted for age, gender, CCI, surgeon, and institution. Subanalyses were performed on indications for revision. A power analysis demonstrated the ability to measure a difference as small as one-half SD between risk of revision within each cohort (specifically, moderate effect sizes based on Cohen d).
resultsAfter controlling for potentially confounding variables, such as surgeon, location of surgery, and patient comorbidity profile, we found no difference regarding odds of all-cause revision between robotic-assisted and nonrobotic-assisted cementless TKA (OR of robotic-assisted versus nonrobotic-assisted cementless TKA 0.8 [95% CI 0.5 to 1.3]; p = 0.41). There were no differences in reasons for revision between robotic-assisted and nonrobotic-assisted cementless TKA, such as mechanical loosening (OR 3.2 [95% CI 0.8 to 12]; p = 0.09) and infection (OR 1.5 [95% CI 0.8 to 2.6]; p = 0.19).
conclusionWe found no evidence that robotic assistance improves the odds of cementless implant survival free from revision at 2 years. Importantly, the differences in odds of revision beyond 2 years as a function of robotic assistance in cementless TKA remains unknown and warrants further population-level investigation, but until or unless robotic assistance proves its value in well-designed studies in terms of endpoints that patients can perceive (such as pain, function, or survivorship), we recommend against widespread adoption until further evidence becomes available. Additionally, we encourage surgeons and healthcare facilities using robotic assistance in cementless TKAs to study its impact on patient outcomes, if any. LEVEL OF EVIDENCE: Level III, therapeutic study.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.